<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glaucoma</journal-id><journal-title-group><journal-title xml:lang="ru">Национальный журнал Глаукома</journal-title><trans-title-group xml:lang="en"><trans-title>National Journal glaucoma</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2078-4104</issn><issn pub-type="epub">2311-6862</issn><publisher><publisher-name>Federal State Budgetary Institution of Science “Krasnov Research Institute of Eye Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.53432/2078-4104-2024-23-1-96-111</article-id><article-id custom-type="elpub" pub-id-type="custom">glaucoma-511</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ ЛИТЕРАТУРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>LITERATURE REVIEWS</subject></subj-group></article-categories><title-group><article-title>Клапанная дренажная система Ahmed в хирургии глаукомы</article-title><trans-title-group xml:lang="en"><trans-title>Ahmed glaucoma valve implantation in glaucoma surgery</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6147-5593</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Расческов</surname><given-names>А. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Rascheskov</surname><given-names>A. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Расческов А. Ю., к.м.н., главный врач</p><p>420000, Казань, ул. Патриса Лумумбы, 28А</p></bio><bio xml:lang="en"><p>Rascheskov A. Yu., Cand. Sci. (Med.), Chief Physician</p><p>28А Patrisa Lumumbi St., Kazan, 420000</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0057-3338</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лоскутов</surname><given-names>И. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Loskoutov</surname><given-names>I. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Лоскутов И. А., д.м.н., заведующий кафедрой офтальмологии и оптометрии; главный внештатный специалист-офтальмолог</p><p>129110, Москва, ул. Щепкина, 61/2</p><p>143407, Московская область, Красногорск, бульвар Строителей, 1</p></bio><bio xml:lang="en"><p>Loskoutov I. A., Dr. Sci. (Med.), Head of the Academic Department of Ophthalmology and Optometry; Chief External Specialist for ophthalmology</p><p>61/2 Shepkina St., Moscow, 129110;</p><p>1 Stroiteley blvd., Karsnogorsk, Moscow Region, 143407</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Корнеева</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Korneeva</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Корнеева Алина Владимировна, к.м.н., главный врач</p><p>121205, Москва, территория ИЦ «Сколково», Большой бульвар, 46, стр. 1.</p></bio><bio xml:lang="en"><p>Korneeva A. V., Cand. Sci. (Med.), ophthalmologist</p><p>46 bld. 1 Bolshoi blvd., Skolkovo Innovation Center, Moscow, 121205.</p></bio><email xlink:type="simple">a.korneeva@skolkovomed.com</email><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ООО «Глазная хирургия Расческов»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>OOO Glaznaya Khirurgiya Rascheskov</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ГБУЗ МО «Московский областной научно-исследовательский клинический институт имени М.Ф. Владимирского»; Министерство здравоохранения Московской области</institution><country>Россия</country></aff><aff xml:lang="en"><institution>M.F. Vladimirsky Moscow Regional Research and Clinical Institute (MONIKI); Ministry of Healthcare of the Moscow Region</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>Филиал компании с ограниченной ответственностью «Хадасса Медикал Лтд»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Branch of Hadassah Medical Ltd.</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>26</day><month>04</month><year>2024</year></pub-date><volume>23</volume><issue>1</issue><fpage>96</fpage><lpage>111</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Расческов А.Ю., Лоскутов И.А., Корнеева А.В., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Расческов А.Ю., Лоскутов И.А., Корнеева А.В.</copyright-holder><copyright-holder xml:lang="en">Rascheskov A.Y., Loskoutov I.A., Korneeva A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.glaucomajournal.ru/jour/article/view/511">https://www.glaucomajournal.ru/jour/article/view/511</self-uri><abstract><p>Глаукома представляет собой значимую медикосоциальную проблему. Несмотря на большое разнообразие подходов к лечению глаукомы, подавляющее большинство исследователей полагают, что именно хирургическое лечение остается наиболее эффективным способом нормализации уровня внутриглазного давления и сохранения зрительных функций. Трабекулэктомия и имплантация дренажного устройства являются наиболее часто выполняемыми операциями при глаукоме во всем мире. Хотя трабекулэктомия является «золотым стандартом», в настоящее время наблюдается увеличение частоты использования дренажных устройств при глаукоме. Клапанная дренажная система (КДС) Ahmed является одним из наиболее широко используемых в мире дренажных устройств при глаукоме. В настоящем литературном обзоре обсуждаются данные наиболее актуальных исследований по результатам имплантации КДС, возможным осложнениям и способам оптимизации этого вида вмешательства в хирургии глаукомы.</p></abstract><trans-abstract xml:lang="en"><p>Glaucoma is the leading cause of irreversible blindness worldwide. Despite the large variety of treatment methods used in glaucoma, most researchers believe that surgery is the most effective way to normalize the level of intraocular pressure and preserve visual functions. Trabeculectomy and glaucoma drainage implantation are the most commonly performed glaucoma surgeries. Although trabeculectomy is the gold standard, at present time there is an uptrend in the use of glaucoma drainage devices. Ahmed glaucoma valve (AGV) is one of the most widely used glaucoma drainage devices in the world. This review of literature presents contemporary results of AGV implantation, possible complications and ways of optimizing that technique.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>глаукома</kwd><kwd>клапанный дренаж Ахмеда</kwd><kwd>внутриглазное давление</kwd></kwd-group><kwd-group xml:lang="en"><kwd>glaucoma</kwd><kwd>Ahmed glaucoma valve</kwd><kwd>intraocular pressure</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Первичная открытоугольная глаукома. Национальное руководство. Под ред. Е.А. Егорова, А.В. Куроедова. М: ГЭОТАР-Медиа 2023, 1032. https://www.rosmedlib.ru/book/ISBN9785970476611.html.</mixed-citation><mixed-citation xml:lang="en">Pervichnaya otkrytougol’naya glaucoma. Natsional’noe rukovodstvo [Primary open-angle glaucoma. National guidelines]. Eds. E.A. Egorov, A.V. Kuroyedov. Moscow, GEOTAR-Media Publ., 2023. 1032 p. https://www.rosmedlib.ru/book/ISBN9785970476611.html.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Tham Y.C., Li X., Wong T. Y., Quigley H.A., et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmol 2014; 121(11):2081-2090. https://doi.org/10.1016/j.ophtha.2014.05.013.</mixed-citation><mixed-citation xml:lang="en">Tham Y.C., Li X., Wong T. Y., Quigley H.A., et al. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmol 2014; 121(11):2081-2090. https://doi.org/10.1016/j.ophtha.2014.05.013.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">European Glaucoma Society Terminology and Guidelines for Glaucoma (5th Edition). Savona, PubliComm, 2020. 169 p. https://doi.org/10.1136/bjophthalmol-2021-egsguidelines.</mixed-citation><mixed-citation xml:lang="en">European Glaucoma Society Terminology and Guidelines for Glaucoma (5th Edition). Savona, PubliComm, 2020. 169 p. https://doi.org/10.1136/bjophthalmol-2021-egsguidelines.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Arikan G, Gunenc U. Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives. Clin Ophthalmol 2023; 17:1833-1845. https://doi.org/10.2147/OPTH.S342721.</mixed-citation><mixed-citation xml:lang="en">Arikan G, Gunenc U. Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives. Clin Ophthalmol 2023; 17:1833-1845. https://doi.org/10.2147/OPTH.S342721.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Jeffrey R., SooHoo M.D., Leonard K., Seibold M., et al. Minimally invasive glaucoma surgery: current implants and future innovations. Can J Ophthalmol 2014; 49(6):528–533. https://doi.org/10.1016/j.jcjo.2014.09.002.</mixed-citation><mixed-citation xml:lang="en">Jeffrey R., SooHoo M.D., Leonard K., Seibold M., et al. Minimally invasive glaucoma surgery: current implants and future innovations. Can J Ophthalmol 2014; 49(6):528–533. https://doi.org/10.1016/j.jcjo.2014.09.002.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Brandгo L.M., Grieshaber M.C. Update on minimally invasive glaucoma surgery (MIGS) and new implants. J Ophthalmol 2013; 2013: 705915. https://doi.org/10.1155/2013/705915.</mixed-citation><mixed-citation xml:lang="en">Brandгo L.M., Grieshaber M.C. Update on minimally invasive glaucoma surgery (MIGS) and new implants. J Ophthalmol 2013; 2013: 705915. https://doi.org/10.1155/2013/705915.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Richter G. M., Coleman A.L. Minimally invasive glaucoma surgery: current status and future prospects. Clin Ophthalmol 2016; 10:189–206. https://doi.org/10.2147/OPTH.S80490.</mixed-citation><mixed-citation xml:lang="en">Richter G. M., Coleman A.L. Minimally invasive glaucoma surgery: current status and future prospects. Clin Ophthalmol 2016; 10:189–206. https://doi.org/10.2147/OPTH.S80490.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Basic and Clinical Science Course 2022-2023. Section 10. Glaucoma. Ed. A.P. Tanna. San Francisco, AAO, 2022. 319 p.</mixed-citation><mixed-citation xml:lang="en">Basic and Clinical Science Course 2022-2023. Section 10. Glaucoma. Ed. A.P. Tanna. San Francisco, AAO, 2022. 319 p.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Stephenson M. Tips and techniques for optimizing approved MIGS. EyeWorld Asia-Pacific 2017; 13(3):22-24.</mixed-citation><mixed-citation xml:lang="en">Stephenson M. Tips and techniques for optimizing approved MIGS. EyeWorld Asia-Pacific 2017; 13(3):22-24.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Tseng V.L., Coleman A.L., Chang M.Y. Aqueous shunts for glaucoma. Cochrane Database Syst Rev 2017; 7:CD004918. https://doi.org/10.1002/14651858.CD004918.pub3.</mixed-citation><mixed-citation xml:lang="en">Tseng V.L., Coleman A.L., Chang M.Y. Aqueous shunts for glaucoma. Cochrane Database Syst Rev 2017; 7:CD004918. https://doi.org/10.1002/14651858.CD004918.pub3.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Patel S., Pasquale L.R. Glaucoma drainage devices: a review of the past, present, and future. Semin Ophthalmol 2010; 25(5–6):265–270. https://doi.org/10.3109/08820538.2010.518840.</mixed-citation><mixed-citation xml:lang="en">Patel S., Pasquale L.R. Glaucoma drainage devices: a review of the past, present, and future. Semin Ophthalmol 2010; 25(5–6):265–270. https://doi.org/10.3109/08820538.2010.518840.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Vinod K., Gedde S.J., Feuer W.J., Panarelli J.F., et al. Practice preferences for glaucoma surgery: a survey of the American Glaucoma Society. J Glaucoma 2017; 26 (8):687–693. https://doi.org/10.1097/IJG.0000000000000720.</mixed-citation><mixed-citation xml:lang="en">Vinod K., Gedde S.J., Feuer W.J., Panarelli J.F., et al. Practice preferences for glaucoma surgery: a survey of the American Glaucoma Society. J Glaucoma 2017; 26 (8):687–693. https://doi.org/10.1097/IJG.0000000000000720.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Murphy C., Ogston S., Cobb C., MacEwen C. Recent trends in glaucoma surgery in Scotland, England and Wales. Br J Ophthalmol 2015; 99(3):308–312. https://doi.org/10.1136/bjophthalmol-2013-304465</mixed-citation><mixed-citation xml:lang="en">Murphy C., Ogston S., Cobb C., MacEwen C. Recent trends in glaucoma surgery in Scotland, England and Wales. Br J Ophthalmol 2015; 99(3):308–312. https://doi.org/10.1136/bjophthalmol-2013-304465</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Bron A.M., Mariet A.S., Benzenine E., Arnould L., et al. Trends in operating room-based glaucoma procedures in France from 2005 to 2014: a nationwide study. Br J Ophthalmol 2017; 101(11):1500–1504. https://doi.org/10.1136/bjophthalmol-2016-309946.</mixed-citation><mixed-citation xml:lang="en">Bron A.M., Mariet A.S., Benzenine E., Arnould L., et al. Trends in operating room-based glaucoma procedures in France from 2005 to 2014: a nationwide study. Br J Ophthalmol 2017; 101(11):1500–1504. https://doi.org/10.1136/bjophthalmol-2016-309946.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Arora K.S., Robin A.L., Corcoran K.J., Corcoran S.L., et al. Use of various glaucoma surgeries and procedures in medicare beneficiaries from 1994 to 2012. Ophthalmology 2015; 122(8):1615–1624. https://doi.org/10.1016/j.ophtha.2015.04.015.</mixed-citation><mixed-citation xml:lang="en">Arora K.S., Robin A.L., Corcoran K.J., Corcoran S.L., et al. Use of various glaucoma surgeries and procedures in medicare beneficiaries from 1994 to 2012. Ophthalmology 2015; 122(8):1615–1624. https://doi.org/10.1016/j.ophtha.2015.04.015.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Gedde S.J., Schiffman J.C., Feuer W.J., Herndon L.W., et al. Treatment outcomes in the Tube Versus Trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol 2012; 153:789–803. https://doi.org/10.1016/j.ajo.2011.10.026.</mixed-citation><mixed-citation xml:lang="en">Gedde S.J., Schiffman J.C., Feuer W.J., Herndon L.W., et al. Treatment outcomes in the Tube Versus Trabeculectomy (TVT) study after five years of follow-up. Am J Ophthalmol 2012; 153:789–803. https://doi.org/10.1016/j.ajo.2011.10.026.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Gedde S.J., Feuer W.J., Shi W., Lim K.S., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 1 year of followup. Ophthalmology 2018; 125:650–663. https://doi.org/10.1016/j.ophtha.2018.02.003.</mixed-citation><mixed-citation xml:lang="en">Gedde S.J., Feuer W.J., Shi W., Lim K.S., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 1 year of followup. Ophthalmology 2018; 125:650–663. https://doi.org/10.1016/j.ophtha.2018.02.003.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Gedde S.J., Feuer W.J., Lim K.S., Barton K., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 3 years of follow-up. Ophthalmology 2020; 127:333–345. https://doi.org/10.1016/j.ophtha.2019.10.002.</mixed-citation><mixed-citation xml:lang="en">Gedde S.J., Feuer W.J., Lim K.S., Barton K., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 3 years of follow-up. Ophthalmology 2020; 127:333–345. https://doi.org/10.1016/j.ophtha.2019.10.002.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Gedde S.J., Feuer W.J., Lim K.S., Barton K., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 5 years of follow-up. Ophthalmology 2022; 129:1344–1356. https://doi.org/10.1016/j.ophtha.2022.07.003.</mixed-citation><mixed-citation xml:lang="en">Gedde S.J., Feuer W.J., Lim K.S., Barton K., et al. Treatment outcomes in the Primary Tube Versus Trabeculectomy Study after 5 years of follow-up. Ophthalmology 2022; 129:1344–1356. https://doi.org/10.1016/j.ophtha.2022.07.003.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Eksioglu U., Yakin M., Sungur G., Satana B., et al. Short-to long-term results of Ahmed glaucoma valve in the management of elevated intraocular pressure in patients with pediatric uveitis. Can J Ophthalmol 2017; 52(3):295–301. https://doi.org/10.1016/j.jcjo.2016.11.015.</mixed-citation><mixed-citation xml:lang="en">Eksioglu U., Yakin M., Sungur G., Satana B., et al. Short-to long-term results of Ahmed glaucoma valve in the management of elevated intraocular pressure in patients with pediatric uveitis. Can J Ophthalmol 2017; 52(3):295–301. https://doi.org/10.1016/j.jcjo.2016.11.015.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Pakravan M., Esfandiari H., Yazdani S., Doozandeh A., et al. Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma. Eur J Ophthalmol 2019; 29(1):44–51. https://doi.org/10.1177/1120672118761332.</mixed-citation><mixed-citation xml:lang="en">Pakravan M., Esfandiari H., Yazdani S., Doozandeh A., et al. Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma. Eur J Ophthalmol 2019; 29(1):44–51. https://doi.org/10.1177/1120672118761332.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Spiess K., Calvo J.P. Outcomes of Ahmed glaucoma valve in paediatric glaucoma following congenital cataract surgery in persistent fetal vasculature. Eur J Ophthalmol 2021; 31(3):1070-1078. https://doi.org/10.1177/1120672120919066.</mixed-citation><mixed-citation xml:lang="en">Spiess K., Calvo J.P. Outcomes of Ahmed glaucoma valve in paediatric glaucoma following congenital cataract surgery in persistent fetal vasculature. Eur J Ophthalmol 2021; 31(3):1070-1078. https://doi.org/10.1177/1120672120919066.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Jacobson A., Bohnsack B.L. Ahmed to Baerveldt glaucoma drainage device exchange in pediatric patients. BMC Ophthalmol 2023; 23(1): 310. https://doi.org/10.1186/s12886-023-03074-1.</mixed-citation><mixed-citation xml:lang="en">Jacobson A., Bohnsack B.L. Ahmed to Baerveldt glaucoma drainage device exchange in pediatric patients. BMC Ophthalmol 2023; 23(1): 310. https://doi.org/10.1186/s12886-023-03074-1.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Rosentreter A., Mellein A.C., Konen W.W., Dietlein T.S. Capsule excision and Ologen implantation for revision after glaucoma drainage device surgery. Graefes Arch Clin Exp Ophthalmol 2010; 248:1319-1324. https://doi.org/10.1007/s00417-010-1385-y.</mixed-citation><mixed-citation xml:lang="en">Rosentreter A., Mellein A.C., Konen W.W., Dietlein T.S. Capsule excision and Ologen implantation for revision after glaucoma drainage device surgery. Graefes Arch Clin Exp Ophthalmol 2010; 248:1319-1324. https://doi.org/10.1007/s00417-010-1385-y.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Lai J.S., Poon A.S., Chua J.K., Tham C.C., et al. Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma. Br J Ophthalmol 2000; 84:718-721. https://doi.org/10.1136/bjo.84.7.718.</mixed-citation><mixed-citation xml:lang="en">Lai J.S., Poon A.S., Chua J.K., Tham C.C., et al. Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma. Br J Ophthalmol 2000; 84:718-721. https://doi.org/10.1136/bjo.84.7.718.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Coleman A.L., Smyth R.J., Wilson M.R., Tam M. Initial clinical experience with the Ahmed glaucoma valve implant in pediatric patients. Arch Ophthalmol 1997; 115:186-191. https://doi.org/10.1001/archopht.1997.01100150188007.</mixed-citation><mixed-citation xml:lang="en">Coleman A.L., Smyth R.J., Wilson M.R., Tam M. Initial clinical experience with the Ahmed glaucoma valve implant in pediatric patients. Arch Ophthalmol 1997; 115:186-191. https://doi.org/10.1001/archopht.1997.01100150188007.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Yang H.K., Park K.H. Clinical outcomes after Ahmed valve implantation in refractory paediatric glaucoma. Eye (Lond) 2009; 23:1427-1435. https://doi.org/10.1038/eye.2008.261.</mixed-citation><mixed-citation xml:lang="en">Yang H.K., Park K.H. Clinical outcomes after Ahmed valve implantation in refractory paediatric glaucoma. Eye (Lond) 2009; 23:1427-1435. https://doi.org/10.1038/eye.2008.261.</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Goulet R.J. 3rd, Phan A.D., Cantor L.B., WuDunn D. Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant. Ophthalmology 2008; 115:1141-1147. https://doi.org/10.1016/j.ophtha.2007.10.034.</mixed-citation><mixed-citation xml:lang="en">Goulet R.J. 3rd, Phan A.D., Cantor L.B., WuDunn D. Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant. Ophthalmology 2008; 115:1141-1147. https://doi.org/10.1016/j.ophtha.2007.10.034.</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">HaiBo T., Xin K., ShiHeng L., Lin L. Comparison of Ahmed glaucoma valve implantation and trabeculectomy for glaucoma: A systematic review and meta-analysis. PLoS One 2015; 10: e0118142. https://doi.org/10.1371/journal.pone.0118142.</mixed-citation><mixed-citation xml:lang="en">HaiBo T., Xin K., ShiHeng L., Lin L. Comparison of Ahmed glaucoma valve implantation and trabeculectomy for glaucoma: A systematic review and meta-analysis. PLoS One 2015; 10: e0118142. https://doi.org/10.1371/journal.pone.0118142.</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Инструкция по применению медицинского изделия клапана глаукоматозного Ахмед модели FP7, FP8. http://ahmedglaucoma.ru/index.php?option=com_content&amp;task= view&amp;id=6&amp;Itemid=13</mixed-citation><mixed-citation xml:lang="en">Introductions. Application at medical device The Ahmed Glaucoma Valve, models FP7, FP8. http://ahmedglaucoma.ru/index.php?option=com_content&amp;task=vi ew&amp;id=6&amp;Itemid=13</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Siriwardena D., Khaw P. T., King A. J. Human antitransformig growth factor beta-2 monoclonal antibody: a new modulator of wound healing in trabeculectomy: a randomized placebo controlled clinical study. Ophthalmology 2002; 109:427-431. https://doi.org/10.1016/s0161-6420(01)00997-6.</mixed-citation><mixed-citation xml:lang="en">Siriwardena D., Khaw P. T., King A. J. Human antitransformig growth factor beta-2 monoclonal antibody: a new modulator of wound healing in trabeculectomy: a randomized placebo controlled clinical study. Ophthalmology 2002; 109:427-431. https://doi.org/10.1016/s0161-6420(01)00997-6.</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Бакунина Н. А. Комбинированное хирургическое лечение некоторых форм рефрактерной глаукомы: автореф. … канд. мед. наук / Н. А. Бакунина. – М., 2006. – 26 с. https://www.dissercat.com/content/kombinirovannoe-khirurgi-cheskoe-lechenie-nekotorykh-form-refrakternoi-glaukomy</mixed-citation><mixed-citation xml:lang="en">Bakunina N.A. Combined surgical treatment of some forms of refractory glaucoma: abstract… Сand. Sci. – M., 2006. - 26 p. https://www.dissercat.com/content/kombinirovannoe-khirurgicheskoe-lechenie-nekotorykh-form-refrakternoi-glaukomy</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Kim J.Y., Lee JS, Lee T. Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement. Sci Rep 2021; 11(1):12986. https://doi.org/10.1038/s41598-021-92420-8.</mixed-citation><mixed-citation xml:lang="en">Kim J.Y., Lee JS, Lee T. Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement. Sci Rep 2021; 11(1):12986. https://doi.org/10.1038/s41598-021-92420-8.</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Christakis P.G., Zhang D., Budenz D.L, Barton K., et al. Five-year pooled data analysis of the Ahmed Baerveldt comparison study and the Ahmed versus Baerveldt study. Am J Ophthalmol 2017; 176:118–126. https://doi.org/10.1016/j.ajo.2017.01.003.</mixed-citation><mixed-citation xml:lang="en">Christakis P.G., Zhang D., Budenz D.L, Barton K., et al. Five-year pooled data analysis of the Ahmed Baerveldt comparison study and the Ahmed versus Baerveldt study. Am J Ophthalmol 2017; 176:118–126. https://doi.org/10.1016/j.ajo.2017.01.003.</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Budenz D.L., Barton K., Feuer W.J. Treatment outcomes in the Ahmed Baerveldt Comparison Study after 1 year of follow-up. Ophthalmology 2011; 118:443–452. https://doi.org/10.1016/j.ophtha.2010.07.016.</mixed-citation><mixed-citation xml:lang="en">Budenz D.L., Barton K., Feuer W.J. Treatment outcomes in the Ahmed Baerveldt Comparison Study after 1 year of follow-up. Ophthalmology 2011; 118:443–452. https://doi.org/10.1016/j.ophtha.2010.07.016.</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Barton K., Feuer W.J., Budenz D.L. Three-year treatment outcomes in the Ahmed Baerveldt Comparison study. Ophthalmology 2014; 121:1547–1557. https://doi.org/10.1016/j.ophtha.2014.01.036.</mixed-citation><mixed-citation xml:lang="en">Barton K., Feuer W.J., Budenz D.L. Three-year treatment outcomes in the Ahmed Baerveldt Comparison study. Ophthalmology 2014; 121:1547–1557. https://doi.org/10.1016/j.ophtha.2014.01.036.</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Budenz D.L., Barton K., Gedde S.J. Five-year treatment outcomes in the Ahmed Baerveldt comparison study. Ophthalmology 2015; 122(2):308–316. https://doi.org/10.1016/j.ophtha.2014.08.043.</mixed-citation><mixed-citation xml:lang="en">Budenz D.L., Barton K., Gedde S.J. Five-year treatment outcomes in the Ahmed Baerveldt comparison study. Ophthalmology 2015; 122(2):308–316. https://doi.org/10.1016/j.ophtha.2014.08.043.</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Christakis P.G., Kalenak J.W., Zurakowski D. The Ahmed versus Baerveldt study. One-year treatment outcomes. Ophthalmology 2011; 118:2180–2189. https://doi.org/10.1016/j.ophtha.2011.05.004.</mixed-citation><mixed-citation xml:lang="en">Christakis P.G., Kalenak J.W., Zurakowski D. The Ahmed versus Baerveldt study. One-year treatment outcomes. Ophthalmology 2011; 118:2180–2189. https://doi.org/10.1016/j.ophtha.2011.05.004.</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Christakis P.G., Tsai J.C., Kalenak J.W. The Ahmed versus Baerveldt study. Three-year treatment outcomes. Ophthalmology 2013; 120:2232–2240. https://doi.org/10.1016/j.ophtha.2013.04.018.</mixed-citation><mixed-citation xml:lang="en">Christakis P.G., Tsai J.C., Kalenak J.W. The Ahmed versus Baerveldt study. Three-year treatment outcomes. Ophthalmology 2013; 120:2232–2240. https://doi.org/10.1016/j.ophtha.2013.04.018.</mixed-citation></citation-alternatives></ref><ref id="cit40"><label>40</label><citation-alternatives><mixed-citation xml:lang="ru">Christakis P.G., Kalenak J.W., Tsai J.C. The Ahmed versus Baerveldt study: five-year treatment outcomes. Ophthalmology 2016; 123(10): 2093–2102. https://doi.org/10.1016/j.ophtha.2016.06.035.</mixed-citation><mixed-citation xml:lang="en">Christakis P.G., Kalenak J.W., Tsai J.C. The Ahmed versus Baerveldt study: five-year treatment outcomes. Ophthalmology 2016; 123(10): 2093–2102. https://doi.org/10.1016/j.ophtha.2016.06.035.</mixed-citation></citation-alternatives></ref><ref id="cit41"><label>41</label><citation-alternatives><mixed-citation xml:lang="ru">Pandav S.S., Seth N.G., Thattaruthody F. Long-term outcome of lowcost glaucoma drainage device (Aurolab aqueous drainage implant) compared with Ahmed glaucoma valve. Br J Ophthalmol 2019; 104(4):557-562. https://doi.org/10.1136/bjophthalmol-2019-313942.</mixed-citation><mixed-citation xml:lang="en">Pandav S.S., Seth N.G., Thattaruthody F. Long-term outcome of lowcost glaucoma drainage device (Aurolab aqueous drainage implant) compared with Ahmed glaucoma valve. Br J Ophthalmol 2019; 104(4):557-562. https://doi.org/10.1136/bjophthalmol-2019-313942.</mixed-citation></citation-alternatives></ref><ref id="cit42"><label>42</label><citation-alternatives><mixed-citation xml:lang="ru">Yalvac I.S., Eksioglu U., Satana B., Duman S. Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucoma. Eye 2007; 21(1):65–70. https://doi.org/10.1038/sj.eye.6702125.</mixed-citation><mixed-citation xml:lang="en">Yalvac I.S., Eksioglu U., Satana B., Duman S. Long-term results of Ahmed glaucoma valve and Molteno implant in neovascular glaucoma. Eye 2007; 21(1):65–70. https://doi.org/10.1038/sj.eye.6702125.</mixed-citation></citation-alternatives></ref><ref id="cit43"><label>43</label><citation-alternatives><mixed-citation xml:lang="ru">Topouzis F., Coleman A.L., Choplin N. Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 1999; 128:198-204. https://doi.org/10.1016/s0002-9394(99)00080-x.</mixed-citation><mixed-citation xml:lang="en">Topouzis F., Coleman A.L., Choplin N. Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 1999; 128:198-204. https://doi.org/10.1016/s0002-9394(99)00080-x.</mixed-citation></citation-alternatives></ref><ref id="cit44"><label>44</label><citation-alternatives><mixed-citation xml:lang="ru">Ishida K., Netland P.A, Costa V.P., Shiroma L., Khan B., Ahmed I.I. Comparison of polypropylene and silicone Ahmed Glaucoma Valves. Ophthalmology 2006; 113(8):1320–1326. https://doi.org/10.1016/j.ophtha.2006.04.020.</mixed-citation><mixed-citation xml:lang="en">Ishida K., Netland P.A, Costa V.P., Shiroma L., Khan B., Ahmed I.I. Comparison of polypropylene and silicone Ahmed Glaucoma Valves. Ophthalmology 2006; 113(8):1320–1326. https://doi.org/10.1016/j.ophtha.2006.04.020.</mixed-citation></citation-alternatives></ref><ref id="cit45"><label>45</label><citation-alternatives><mixed-citation xml:lang="ru">Hinkle D.M., Zurakowski D., Ayyala R.S. A comparison of the polypropylene plate Ahmed glaucoma valve to the silicone plate Ahmed glaucoma flexible valve. Eur J Ophthalmol 2007; 17(5):696–701. https://doi.org/10.1177/112067210701700502.</mixed-citation><mixed-citation xml:lang="en">Hinkle D.M., Zurakowski D., Ayyala R.S. A comparison of the polypropylene plate Ahmed glaucoma valve to the silicone plate Ahmed glaucoma flexible valve. Eur J Ophthalmol 2007; 17(5):696–701. https://doi.org/10.1177/112067210701700502.</mixed-citation></citation-alternatives></ref><ref id="cit46"><label>46</label><citation-alternatives><mixed-citation xml:lang="ru">Siempis T., Younus O., Makuloluwa A. Long-Term Outcomes of Ahmed Glaucoma Valve Surgery in a Scottish Cohort of Patients With Refractory Glaucoma. Cureus 2023; 15(3):358-377. https://doi.org/10.7759/cureus.35877.</mixed-citation><mixed-citation xml:lang="en">Siempis T., Younus O., Makuloluwa A. Long-Term Outcomes of Ahmed Glaucoma Valve Surgery in a Scottish Cohort of Patients With Refractory Glaucoma. Cureus 2023; 15(3):358-377. https://doi.org/10.7759/cureus.35877.</mixed-citation></citation-alternatives></ref><ref id="cit47"><label>47</label><citation-alternatives><mixed-citation xml:lang="ru">Xie Z., Liu H., Du M., Zhu M., et al. Efficacy of Ahmed glaucoma valve implantation on neovascular glaucoma. Int J Med Sci 2019; 16:1371-1376. https://doi.org/10.7150/ijms.35267.</mixed-citation><mixed-citation xml:lang="en">Xie Z., Liu H., Du M., Zhu M., et al. Efficacy of Ahmed glaucoma valve implantation on neovascular glaucoma. Int J Med Sci 2019; 16:1371-1376. https://doi.org/10.7150/ijms.35267.</mixed-citation></citation-alternatives></ref><ref id="cit48"><label>48</label><citation-alternatives><mixed-citation xml:lang="ru">Netland PA. The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis). Trans Am Ophthalmol Soc 2009; 107:325-342. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2814575/pdf/1545-6110_v107</mixed-citation><mixed-citation xml:lang="en">Netland PA. The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis). Trans Am Ophthalmol Soc 2009; 107:325-342. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2814575/pdf/1545-6110_v107</mixed-citation></citation-alternatives></ref><ref id="cit49"><label>49</label><citation-alternatives><mixed-citation xml:lang="ru">Bowden E.C, Choudhury A., Gedde S.J., et al. Risk factors for failure of tube shunt surgery: a pooled data analysis. Am J Ophthalmol 2022; 240:217–224. https://doi.org/10.1016/j.ajo.2022.02.027.</mixed-citation><mixed-citation xml:lang="en">Bowden E.C, Choudhury A., Gedde S.J., et al. Risk factors for failure of tube shunt surgery: a pooled data analysis. Am J Ophthalmol 2022; 240:217–224. https://doi.org/10.1016/j.ajo.2022.02.027.</mixed-citation></citation-alternatives></ref><ref id="cit50"><label>50</label><citation-alternatives><mixed-citation xml:lang="ru">Souza C., Tran D.H., Loman J., Law S.K.,et al. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol 2007; 144(6):893–900. https://doi.org/10.1016/j.ajo.2007.07.035.</mixed-citation><mixed-citation xml:lang="en">Souza C., Tran D.H., Loman J., Law S.K.,et al. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol 2007; 144(6):893–900. https://doi.org/10.1016/j.ajo.2007.07.035.</mixed-citation></citation-alternatives></ref><ref id="cit51"><label>51</label><citation-alternatives><mixed-citation xml:lang="ru">Ramji S., Nagi G., Ansari A. S., Kailani O. A systematic review and meta-analysis of randomised controlled trials in the management of neovascular glaucoma: absence of consensus and variability in practice. Graefe's Arch Clin Exp Ophthalmol 2023; 261:477–501. https://doi.org/10.1007/s00417-022-05785-5.</mixed-citation><mixed-citation xml:lang="en">Ramji S., Nagi G., Ansari A. S., Kailani O. A systematic review and meta-analysis of randomised controlled trials in the management of neovascular glaucoma: absence of consensus and variability in practice. Graefe's Arch Clin Exp Ophthalmol 2023; 261:477–501. https://doi.org/10.1007/s00417-022-05785-5.</mixed-citation></citation-alternatives></ref><ref id="cit52"><label>52</label><citation-alternatives><mixed-citation xml:lang="ru">Teixeira S.H., Doi L.M., Freitas Silva A.L., et al. Silicone Ahmed glaucoma valve with and without intravitreal triamcinolone acetonide for neovascular glaucoma: randomized clinical trial. J Glaucoma 2012; 21(5):342–348. https://doi.org/10.1097/IJG.0b013e31820d7e4e.</mixed-citation><mixed-citation xml:lang="en">Teixeira S.H., Doi L.M., Freitas Silva A.L., et al. Silicone Ahmed glaucoma valve with and without intravitreal triamcinolone acetonide for neovascular glaucoma: randomized clinical trial. J Glaucoma 2012; 21(5):342–348. https://doi.org/10.1097/IJG.0b013e31820d7e4e.</mixed-citation></citation-alternatives></ref><ref id="cit53"><label>53</label><citation-alternatives><mixed-citation xml:lang="ru">Minckler D.S., Francis B.A., Hodapp E.A. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology 2008; 115:1089-1098. https://doi.org/10.1016/j.ophtha.2008.03.031.</mixed-citation><mixed-citation xml:lang="en">Minckler D.S., Francis B.A., Hodapp E.A. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology 2008; 115:1089-1098. https://doi.org/10.1016/j.ophtha.2008.03.031.</mixed-citation></citation-alternatives></ref><ref id="cit54"><label>54</label><citation-alternatives><mixed-citation xml:lang="ru">Hwang H.B., Han J.W., Yim H.B. Beneficial effects of adjuvant intravitreal bevacizumab injection on outcomes of Ahmed glaucoma valve implantation in patients with neovascular glaucoma: systematic literature review. J Ocul Pharmacol Ther 2015; 31(4):198–203. https://doi.org/10.1089/jop.2014.0108.</mixed-citation><mixed-citation xml:lang="en">Hwang H.B., Han J.W., Yim H.B. Beneficial effects of adjuvant intravitreal bevacizumab injection on outcomes of Ahmed glaucoma valve implantation in patients with neovascular glaucoma: systematic literature review. J Ocul Pharmacol Ther 2015; 31(4):198–203. https://doi.org/10.1089/jop.2014.0108.</mixed-citation></citation-alternatives></ref><ref id="cit55"><label>55</label><citation-alternatives><mixed-citation xml:lang="ru">Arcieri E.S., Paula JS, Jorge R. Efficacy and safety of intravitreal bevacizumab in eyes with neovascular glaucoma undergoing Ahmed glaucoma valve implantation: 2-year follow-up. Acta Ophthalmol 2015; 93(1):1–6. https://doi.org/10.1111/aos.12493.</mixed-citation><mixed-citation xml:lang="en">Arcieri E.S., Paula JS, Jorge R. Efficacy and safety of intravitreal bevacizumab in eyes with neovascular glaucoma undergoing Ahmed glaucoma valve implantation: 2-year follow-up. Acta Ophthalmol 2015; 93(1):1–6. https://doi.org/10.1111/aos.12493.</mixed-citation></citation-alternatives></ref><ref id="cit56"><label>56</label><citation-alternatives><mixed-citation xml:lang="ru">Choy B., Lai J., Yeung J. Randomized comparative trial of diode laser transscleral cyclophotocoagulation versus Ahmed glaucoma valve for neovascular glaucoma in Chinese – a pilot study. Clin Ophthalmol 2018; 12:2545–2552. https://doi.org/10.2147/OPTH.S188999.</mixed-citation><mixed-citation xml:lang="en">Choy B., Lai J., Yeung J. Randomized comparative trial of diode laser transscleral cyclophotocoagulation versus Ahmed glaucoma valve for neovascular glaucoma in Chinese – a pilot study. Clin Ophthalmol 2018; 12:2545–2552. https://doi.org/10.2147/OPTH.S188999.</mixed-citation></citation-alternatives></ref><ref id="cit57"><label>57</label><citation-alternatives><mixed-citation xml:lang="ru">Lin P., Zhao Q., He J. Comparisons of the short- term effectiveness and safety of surgical treatment for neovascular glaucoma: a systematic review and network meta-analysis. BMJ Open 2022; 12: e051794. https://doi.org/10.1136/bmjopen-2021-051794.</mixed-citation><mixed-citation xml:lang="en">Lin P., Zhao Q., He J. Comparisons of the short- term effectiveness and safety of surgical treatment for neovascular glaucoma: a systematic review and network meta-analysis. BMJ Open 2022; 12: e051794. https://doi.org/10.1136/bmjopen-2021-051794.</mixed-citation></citation-alternatives></ref><ref id="cit58"><label>58</label><citation-alternatives><mixed-citation xml:lang="ru">Mahdy R.A., Nada W.M., Fawzy K.M. Efficacy of intravitreal bevacizumab with panretinal photocoagulation followed by Ahmed valve implantation in neovascular glaucoma. J Glaucoma 2013; 22(9):768– 772. https://doi.org/10.1097/IJG.0b013e318259aec4.</mixed-citation><mixed-citation xml:lang="en">Mahdy R.A., Nada W.M., Fawzy K.M. Efficacy of intravitreal bevacizumab with panretinal photocoagulation followed by Ahmed valve implantation in neovascular glaucoma. J Glaucoma 2013; 22(9):768– 772. https://doi.org/10.1097/IJG.0b013e318259aec4.</mixed-citation></citation-alternatives></ref><ref id="cit59"><label>59</label><citation-alternatives><mixed-citation xml:lang="ru">Zhou M., Xu X., Zhang X. Clinical outcomes of Ahmed glaucoma valve implantation with or without intravitreal bevacizumab pretreatment for neovascular glaucoma: a systematic review and meta-analysis. J Glaucoma 2016; 25:551–557. https://doi.org/10.1097/IJG.0000000000000241.</mixed-citation><mixed-citation xml:lang="en">Zhou M., Xu X., Zhang X. Clinical outcomes of Ahmed glaucoma valve implantation with or without intravitreal bevacizumab pretreatment for neovascular glaucoma: a systematic review and meta-analysis. J Glaucoma 2016; 25:551–557. https://doi.org/10.1097/IJG.0000000000000241.</mixed-citation></citation-alternatives></ref><ref id="cit60"><label>60</label><citation-alternatives><mixed-citation xml:lang="ru">Evans J.R., Michelessi M, Virgili G. Laser photocoagulation for proliferative diabetic retinopathy. Cochrane Database Syst Rev – 2014: CD011234 https://doi.org/10.1002/14651858.</mixed-citation><mixed-citation xml:lang="en">Evans J.R., Michelessi M, Virgili G. Laser photocoagulation for proliferative diabetic retinopathy. Cochrane Database Syst Rev – 2014: CD011234 https://doi.org/10.1002/14651858.</mixed-citation></citation-alternatives></ref><ref id="cit61"><label>61</label><citation-alternatives><mixed-citation xml:lang="ru">Дмитриева А.Л., Мясникова В.В., Авакимян Р.А., Хутим Т. Р. и др. Влияние ингибиторов ангиогенеза на течение послеоперационного периода при имплантации клапана Ахмеда у пациентов с неоваскулярной глаукомой. Национальный журнал глаукома 2022; 21(4):37-47. https://doi.org/10.53432/2078-4104-2022-21-4-37-47.</mixed-citation><mixed-citation xml:lang="en">Dmitrieva A.L., Myasnikova V.V., Avakimyan R.A., Hutim T.R., et al. Impact of angiogenesis inhibitors on the postoperative course of Ahmed valve implantation in patients with neovascular glaucoma. Natsional’nyi Zhurnal Glaukoma 2022; 21(4):37-47. https://doi.org/10.53432/2078-4104-2022-21-4-37-47.</mixed-citation></citation-alternatives></ref><ref id="cit62"><label>62</label><citation-alternatives><mixed-citation xml:lang="ru">Чупров А. Д., Казеннов А. Н., Казеннова И. А. Эффективность имплантации клапана Ахмед при вторичной неоваскулярной глаукоме. Вестник Нац мед-хир центра им. Н.И. Пирогова 2022; 17(4):79-81. https://doi.org/10.25881/20728255_2022_17_4_S1_79.</mixed-citation><mixed-citation xml:lang="en">Chuprov A. D., Kazennov A. N., Kazennova I. A. Effecacy of Ahmed valve implantation in secondary neovascular glaucoma. Vestnik Nats Med-Khir Centra 2022; 17(4):79-81. https://doi.org/10.25881/20728255_2022_17_4_S1_79.</mixed-citation></citation-alternatives></ref><ref id="cit63"><label>63</label><citation-alternatives><mixed-citation xml:lang="ru">Gandhi M., Bhartiya S. (Eds.) Glaucoma Drainage Devices: A Practical Illustrated Guide Illustrated Guide. Springer, 2019. – 171 p.</mixed-citation><mixed-citation xml:lang="en">Gandhi M., Bhartiya S. (Eds.) Glaucoma Drainage Devices: A Practical Illustrated Guide Illustrated Guide. Springer, 2019. – 171 p.</mixed-citation></citation-alternatives></ref><ref id="cit64"><label>64</label><citation-alternatives><mixed-citation xml:lang="ru">Chen J., Gedde SJ. New developments in tube shunt surgery. Curr Opin Ophthalmol 2019; 30:125-131. https://doi.org/10.1097/ICU.0000000000000549.</mixed-citation><mixed-citation xml:lang="en">Chen J., Gedde SJ. New developments in tube shunt surgery. Curr Opin Ophthalmol 2019; 30:125-131. https://doi.org/10.1097/ICU.0000000000000549.</mixed-citation></citation-alternatives></ref><ref id="cit65"><label>65</label><citation-alternatives><mixed-citation xml:lang="ru">Maheshwari D., Rao S, Pawar N. Early outcomes of 21-gauge needleguided ab interno tube sulcus placement of a non-valved implant in pseudophakic eyes. Indian J Ophthalmol 2022; 70:1051-1053. https://doi.org/10.4103/ijo.IJO_2303_21.</mixed-citation><mixed-citation xml:lang="en">Maheshwari D., Rao S, Pawar N. Early outcomes of 21-gauge needleguided ab interno tube sulcus placement of a non-valved implant in pseudophakic eyes. Indian J Ophthalmol 2022; 70:1051-1053. https://doi.org/10.4103/ijo.IJO_2303_21.</mixed-citation></citation-alternatives></ref><ref id="cit66"><label>66</label><citation-alternatives><mixed-citation xml:lang="ru">Bayer A., Onol M. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus. Eye 2017; 31(4):608–614. https://doi.org/10.1038/eye.2016.273.</mixed-citation><mixed-citation xml:lang="en">Bayer A., Onol M. Clinical outcomes of Ahmed glaucoma valve in anterior chamber versus ciliary sulcus. Eye 2017; 31(4):608–614. https://doi.org/10.1038/eye.2016.273.</mixed-citation></citation-alternatives></ref><ref id="cit67"><label>67</label><citation-alternatives><mixed-citation xml:lang="ru">Nitta K., Akiyama H. A New Technique Using a 4-0 Nylon Thread as a Guide for Easy and Precise Tube Insertion of Ahmed Glaucoma Valve Implant Into Ciliary Sulcus. Cureus 2023; 11;15(2):e34854. https://doi.org/10.7759/cureus.34854.</mixed-citation><mixed-citation xml:lang="en">Nitta K., Akiyama H. A New Technique Using a 4-0 Nylon Thread as a Guide for Easy and Precise Tube Insertion of Ahmed Glaucoma Valve Implant Into Ciliary Sulcus. Cureus 2023; 11;15(2):e34854. https://doi.org/10.7759/cureus.34854.</mixed-citation></citation-alternatives></ref><ref id="cit68"><label>68</label><citation-alternatives><mixed-citation xml:lang="ru">Wang B., Li W. Comparison of pars plana with anterior chamber glaucoma drainage device implantation for glaucoma: a meta-analysis. BMC Ophthalmol 2018; 18(1):212. https://doi.org/10.1186/s12886-018-0896-x.</mixed-citation><mixed-citation xml:lang="en">Wang B., Li W. Comparison of pars plana with anterior chamber glaucoma drainage device implantation for glaucoma: a meta-analysis. BMC Ophthalmol 2018; 18(1):212. https://doi.org/10.1186/s12886-018-0896-x.</mixed-citation></citation-alternatives></ref><ref id="cit69"><label>69</label><citation-alternatives><mixed-citation xml:lang="ru">Kumar H., Thulasidas M. Pars plana implantation of glaucoma drainage devices- the way to succeed in refractory glaucoma. Indian J Ophthalmol 2021; 69(7):1650–1651. https://doi.org/10.4103/ijo.IJO_688_21.</mixed-citation><mixed-citation xml:lang="en">Kumar H., Thulasidas M. Pars plana implantation of glaucoma drainage devices- the way to succeed in refractory glaucoma. Indian J Ophthalmol 2021; 69(7):1650–1651. https://doi.org/10.4103/ijo.IJO_688_21.</mixed-citation></citation-alternatives></ref><ref id="cit70"><label>70</label><citation-alternatives><mixed-citation xml:lang="ru">Souza C., Tran D.H., Loman J., Law S.K., et al. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol 2007; 144:893–900. https://doi.org/10.1016/j.ajo.2007.07.035.</mixed-citation><mixed-citation xml:lang="en">Souza C., Tran D.H., Loman J., Law S.K., et al. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol 2007; 144:893–900. https://doi.org/10.1016/j.ajo.2007.07.035.</mixed-citation></citation-alternatives></ref><ref id="cit71"><label>71</label><citation-alternatives><mixed-citation xml:lang="ru">Sidoti P.A., Mosny AY, Ritterband DC, Seedor JA. Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. Ophthalmology 2001; 108:1050–1058. https://doi.org/10.1016/s0161-6420(01)00583-8.</mixed-citation><mixed-citation xml:lang="en">Sidoti P.A., Mosny AY, Ritterband DC, Seedor JA. Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. Ophthalmology 2001; 108:1050–1058. https://doi.org/10.1016/s0161-6420(01)00583-8.</mixed-citation></citation-alternatives></ref><ref id="cit72"><label>72</label><citation-alternatives><mixed-citation xml:lang="ru">Siegner S.W., Netland P.A., Urban R.C. Jr, et al. Clinical experience with the Baerveldt glaucoma drainage implant. Ophthalmology 1995; 102:1298–1307. https://doi.org/10.1016/s0161-6420(95)30871-8.</mixed-citation><mixed-citation xml:lang="en">Siegner S.W., Netland P.A., Urban R.C. Jr, et al. Clinical experience with the Baerveldt glaucoma drainage implant. Ophthalmology 1995; 102:1298–1307. https://doi.org/10.1016/s0161-6420(95)30871-8.</mixed-citation></citation-alternatives></ref><ref id="cit73"><label>73</label><citation-alternatives><mixed-citation xml:lang="ru">Weiner A., Cohn A.D., Balasubramaniam M., et al. Glaucoma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation. J Glaucoma 2010; 19:405– 411. https://doi.org/10.1097/IJG.0b013e3181bdb52d.</mixed-citation><mixed-citation xml:lang="en">Weiner A., Cohn A.D., Balasubramaniam M., et al. Glaucoma tube shunt implantation through the ciliary sulcus in pseudophakic eyes with high risk of corneal decompensation. J Glaucoma 2010; 19:405– 411. https://doi.org/10.1097/IJG.0b013e3181bdb52d.</mixed-citation></citation-alternatives></ref><ref id="cit74"><label>74</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang, Q., Liu Y., Thanapaisal S. The effect of tube location on corneal endothelial cells in patients with Ahmed glaucoma valve. Ophthalmology 2021; 128:218–226. https://doi.org/10.1016/j.ophtha.2020.06.050.</mixed-citation><mixed-citation xml:lang="en">Zhang, Q., Liu Y., Thanapaisal S. The effect of tube location on corneal endothelial cells in patients with Ahmed glaucoma valve. Ophthalmology 2021; 128:218–226. https://doi.org/10.1016/j.ophtha.2020.06.050.</mixed-citation></citation-alternatives></ref><ref id="cit75"><label>75</label><citation-alternatives><mixed-citation xml:lang="ru">Ayyala R.S., Zurakowski D., Smith J.A. A clinical study of the Ahmed glaucoma valve implant in advancedglaucoma. Ophthalmology 1998; 105:1968–1976. https://doi.org/10.1016/S0161-6420(98)91049-1.</mixed-citation><mixed-citation xml:lang="en">Ayyala R.S., Zurakowski D., Smith J.A. A clinical study of the Ahmed glaucoma valve implant in advancedglaucoma. Ophthalmology 1998; 105:1968–1976. https://doi.org/10.1016/S0161-6420(98)91049-1.</mixed-citation></citation-alternatives></ref><ref id="cit76"><label>76</label><citation-alternatives><mixed-citation xml:lang="ru">Eslami Y., Mohammadi M., Fakhraie G. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes. J Glaucoma 2014; 23:115–118. https://doi.org/10.1097/IJG.0b013e318265bc0b.</mixed-citation><mixed-citation xml:lang="en">Eslami Y., Mohammadi M., Fakhraie G. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes. J Glaucoma 2014; 23:115–118. https://doi.org/10.1097/IJG.0b013e318265bc0b.</mixed-citation></citation-alternatives></ref><ref id="cit77"><label>77</label><citation-alternatives><mixed-citation xml:lang="ru">Imamoglu S., Ercalik N. Y., Beser B. G. Ciliary Sulcus Implantation of Ahmed Valve. Beyoglu Eye J 2019; 4(2):115-119. https://doi.org/10.14744/bej.2019.00710.</mixed-citation><mixed-citation xml:lang="en">Imamoglu S., Ercalik N. Y., Beser B. G. Ciliary Sulcus Implantation of Ahmed Valve. Beyoglu Eye J 2019; 4(2):115-119. https://doi.org/10.14744/bej.2019.00710.</mixed-citation></citation-alternatives></ref><ref id="cit78"><label>78</label><citation-alternatives><mixed-citation xml:lang="ru">Asaoka S., Kasuga T, Matsunaga T. Operative complications of glaucoma drainage implant tube insertion through the sulcus for pseudophakic eye. J Glaucoma 2021; 30:169-174. https://doi.org/10.1097/IJG.0000000000001783.</mixed-citation><mixed-citation xml:lang="en">Asaoka S., Kasuga T, Matsunaga T. Operative complications of glaucoma drainage implant tube insertion through the sulcus for pseudophakic eye. J Glaucoma 2021; 30:169-174. https://doi.org/10.1097/IJG.0000000000001783.</mixed-citation></citation-alternatives></ref><ref id="cit79"><label>79</label><citation-alternatives><mixed-citation xml:lang="ru">Moreno-Montañés J., Guirao-Navarro C., Argüeso F. Ab interno implantation of glaucoma drainage devices tubes in the posterior chamber. BMC Ophthalmol 2020; 20(1):66. https://doi.org/10.1186/s12886-020-1329-1.</mixed-citation><mixed-citation xml:lang="en">Moreno-Montañés J., Guirao-Navarro C., Argüeso F. Ab interno implantation of glaucoma drainage devices tubes in the posterior chamber. BMC Ophthalmol 2020; 20(1):66. https://doi.org/10.1186/s12886-020-1329-1.</mixed-citation></citation-alternatives></ref><ref id="cit80"><label>80</label><citation-alternatives><mixed-citation xml:lang="ru">Loayza-Gamboa W., Martel-Ramirez V., Inga-Condezo V. Needle guided ab interno technique for tube insertion through the ciliary sulcus in uncontrolled glaucoma. Eur J Ophthalmol 2022; 32:704-708. https://doi.org/10.1177/11206721211007093.</mixed-citation><mixed-citation xml:lang="en">Loayza-Gamboa W., Martel-Ramirez V., Inga-Condezo V. Needle guided ab interno technique for tube insertion through the ciliary sulcus in uncontrolled glaucoma. Eur J Ophthalmol 2022; 32:704-708. https://doi.org/10.1177/11206721211007093.</mixed-citation></citation-alternatives></ref><ref id="cit81"><label>81</label><citation-alternatives><mixed-citation xml:lang="ru">Moreno-Montañés J., Fantes F., García-Gómez P. Polypropylene sutureguided valve tube for posterior chamber implantation in patients with pseudophakic glaucoma. J Cataract Refract Surg 2008; 34(11):1828- 1831. https://doi.org/10.1016/j.jcrs.2008.05.063.</mixed-citation><mixed-citation xml:lang="en">Moreno-Montañés J., Fantes F., García-Gómez P. Polypropylene sutureguided valve tube for posterior chamber implantation in patients with pseudophakic glaucoma. J Cataract Refract Surg 2008; 34(11):1828- 1831. https://doi.org/10.1016/j.jcrs.2008.05.063.</mixed-citation></citation-alternatives></ref><ref id="cit82"><label>82</label><citation-alternatives><mixed-citation xml:lang="ru">Tojo N., Hayashi A., Consolvo-Ueda T. Baerveldt surgery outcomes: Anterior chamber insertion versus vitreous cavity insertion. Graefes Arch Clin Exp Ophthalmol 2018; 256:2191–2200. https://doi.org/10.1007/s00417-018-4116-4.</mixed-citation><mixed-citation xml:lang="en">Tojo N., Hayashi A., Consolvo-Ueda T. Baerveldt surgery outcomes: Anterior chamber insertion versus vitreous cavity insertion. Graefes Arch Clin Exp Ophthalmol 2018; 256:2191–2200. https://doi.org/10.1007/s00417-018-4116-4.</mixed-citation></citation-alternatives></ref><ref id="cit83"><label>83</label><citation-alternatives><mixed-citation xml:lang="ru">Sidoti P.A., Dunphy T.R., Baerveldt G. Experience with the Baerveldt glaucoma implant in treating neovascular glaucoma. Ophthalmology 1995; 10:1107-1118. https://doi.org/10.1016/s0161-6420(95)30904-9.</mixed-citation><mixed-citation xml:lang="en">Sidoti P.A., Dunphy T.R., Baerveldt G. Experience with the Baerveldt glaucoma implant in treating neovascular glaucoma. Ophthalmology 1995; 10:1107-1118. https://doi.org/10.1016/s0161-6420(95)30904-9.</mixed-citation></citation-alternatives></ref><ref id="cit84"><label>84</label><citation-alternatives><mixed-citation xml:lang="ru">Tojo N., Nakamura T., Ueda T.C., Yanagisawa S., et al. Results of the Baerveldt® glaucoma implant for neovascular glaucoma patients. Nippon Ganka Gakkai Zasshi 2017; 121:138–145. https://pubmed.ncbi.nlm.nih.gov/30080004/</mixed-citation><mixed-citation xml:lang="en">Tojo N., Nakamura T., Ueda T.C., Yanagisawa S., et al. Results of the Baerveldt® glaucoma implant for neovascular glaucoma patients. Nippon Ganka Gakkai Zasshi 2017; 121:138–145. https://pubmed.ncbi.nlm.nih.gov/30080004/</mixed-citation></citation-alternatives></ref><ref id="cit85"><label>85</label><citation-alternatives><mixed-citation xml:lang="ru">Tsoukanas D., Xanthopoulou P., Charonis A.C., Theodossiadis P., et al. Heterologous, fresh, human donor sclera as patch graft material in glaucoma drainage device surgery. J. Glaucoma 2016; 25:558–564. https://doi.org/10.1097/IJG.0000000000000294.</mixed-citation><mixed-citation xml:lang="en">Tsoukanas D., Xanthopoulou P., Charonis A.C., Theodossiadis P., et al. Heterologous, fresh, human donor sclera as patch graft material in glaucoma drainage device surgery. J. Glaucoma 2016; 25:558–564. https://doi.org/10.1097/IJG.0000000000000294.</mixed-citation></citation-alternatives></ref><ref id="cit86"><label>86</label><citation-alternatives><mixed-citation xml:lang="ru">Tamcelik N., Ozkok A., Sarıcı A.M. Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol 2013; 57: 359–364. https://doi.org/10.1007/s10384-013-0249-5.</mixed-citation><mixed-citation xml:lang="en">Tamcelik N., Ozkok A., Sarıcı A.M. Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma. Jpn J Ophthalmol 2013; 57: 359–364. https://doi.org/10.1007/s10384-013-0249-5.</mixed-citation></citation-alternatives></ref><ref id="cit87"><label>87</label><citation-alternatives><mixed-citation xml:lang="ru">Van Hoefen Wijsard M., Haan M., Rietveld E., van Rijn L.J. Donor sclera versus bovine pericardium as patch graft material in glaucoma implant surgery and the impact of a drainage suture. Acta Ophthalmol 2018; 96:692–698. https://doi.org/10.1111/aos.13721.</mixed-citation><mixed-citation xml:lang="en">Van Hoefen Wijsard M., Haan M., Rietveld E., van Rijn L.J. Donor sclera versus bovine pericardium as patch graft material in glaucoma implant surgery and the impact of a drainage suture. Acta Ophthalmol 2018; 96:692–698. https://doi.org/10.1111/aos.13721.</mixed-citation></citation-alternatives></ref><ref id="cit88"><label>88</label><citation-alternatives><mixed-citation xml:lang="ru">Tanji T.M., Lundy D.C., Minckler D.S., Heuer D.K., et al. Fascia lata patch graft in glaucoma tube surgery. Ophthalmology 1996; 103:1309–1312. https://doi.org/10.1016/s0161-6420(96)30506-x.</mixed-citation><mixed-citation xml:lang="en">Tanji T.M., Lundy D.C., Minckler D.S., Heuer D.K., et al. Fascia lata patch graft in glaucoma tube surgery. Ophthalmology 1996; 103:1309–1312. https://doi.org/10.1016/s0161-6420(96)30506-x.</mixed-citation></citation-alternatives></ref><ref id="cit89"><label>89</label><citation-alternatives><mixed-citation xml:lang="ru">Brandt J.D. Patch grafts of dehydrated cadaveric dura mater for tubeshunt glaucoma surgery. Arch Ophthalmol 1993; 111:1436–1439. https://doi.org/10.1001/archopht.1993.01090100144042.</mixed-citation><mixed-citation xml:lang="en">Brandt J.D. Patch grafts of dehydrated cadaveric dura mater for tubeshunt glaucoma surgery. Arch Ophthalmol 1993; 111:1436–1439. https://doi.org/10.1001/archopht.1993.01090100144042.</mixed-citation></citation-alternatives></ref><ref id="cit90"><label>90</label><citation-alternatives><mixed-citation xml:lang="ru">Kugu S., Erdogan G., Sevim M.S., Ozerturk, Y. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol 2015; 30:1–5. https://doi.org/10.3109/08820538.2013.807851.</mixed-citation><mixed-citation xml:lang="en">Kugu S., Erdogan G., Sevim M.S., Ozerturk, Y. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva. Semin Ophthalmol 2015; 30:1–5. https://doi.org/10.3109/08820538.2013.807851.</mixed-citation></citation-alternatives></ref><ref id="cit91"><label>91</label><citation-alternatives><mixed-citation xml:lang="ru">Singh M., Chew P.T., Tan, D. Corneal patch graft repair of exposed glaucoma drainage implants. Cornea 2008; 27:1171–1173. https://doi.org/10.1097/ICO.0b013e3181814d15.</mixed-citation><mixed-citation xml:lang="en">Singh M., Chew P.T., Tan, D. Corneal patch graft repair of exposed glaucoma drainage implants. Cornea 2008; 27:1171–1173. https://doi.org/10.1097/ICO.0b013e3181814d15.</mixed-citation></citation-alternatives></ref><ref id="cit92"><label>92</label><citation-alternatives><mixed-citation xml:lang="ru">Pakravan M., Hatami M., Esfandiari H., Yazdani S., et al. Ahmed glaucoma valve implantation: Graft-free short tunnel small flap versus scleral patch graft after 1-Year follow-up: A randomized clinical trial. Ophthalmol. Glaucoma 2018; 1:206–212. https://doi.org/10.1016/j.ogla.2018.10.008.</mixed-citation><mixed-citation xml:lang="en">Pakravan M., Hatami M., Esfandiari H., Yazdani S., et al. Ahmed glaucoma valve implantation: Graft-free short tunnel small flap versus scleral patch graft after 1-Year follow-up: A randomized clinical trial. Ophthalmol. Glaucoma 2018; 1:206–212. https://doi.org/10.1016/j.ogla.2018.10.008.</mixed-citation></citation-alternatives></ref><ref id="cit93"><label>93</label><citation-alternatives><mixed-citation xml:lang="ru">Ma X.H., Du X.J., Liu B., Bi H.S. Modified scleral tunnel to prevent tube exposure in patients with refractory glaucoma. J Glaucoma 2016; 25:883–885. https://doi.org/10.1097/IJG.0000000000000463.</mixed-citation><mixed-citation xml:lang="en">Ma X.H., Du X.J., Liu B., Bi H.S. Modified scleral tunnel to prevent tube exposure in patients with refractory glaucoma. J Glaucoma 2016; 25:883–885. https://doi.org/10.1097/IJG.0000000000000463.</mixed-citation></citation-alternatives></ref><ref id="cit94"><label>94</label><citation-alternatives><mixed-citation xml:lang="ru">Ozdamar A., Aras C., Karacorlu M. Suprachoroidal seton implantation in refractory glaucoma: A novel surgical technique. J Glaucoma 2003; 12:354–359. https://doi.org/10.1097/00061198-200308000-00010.</mixed-citation><mixed-citation xml:lang="en">Ozdamar A., Aras C., Karacorlu M. Suprachoroidal seton implantation in refractory glaucoma: A novel surgical technique. J Glaucoma 2003; 12:354–359. https://doi.org/10.1097/00061198-200308000-00010.</mixed-citation></citation-alternatives></ref><ref id="cit95"><label>95</label><citation-alternatives><mixed-citation xml:lang="ru">Расческов А. Ю. Способ имплантации дренажного клапана для нормализации внутриглазного давления. Патент на изобретение RUS 2434613, 17.05.2010. https://yandex.ru/patents/doc/RU2434613C1_20111127</mixed-citation><mixed-citation xml:lang="en">Rascheskov A. Yu. Method of glaucoma valve implantion for intraocular pressure normalization. RUS Patent 2434613, 2010 May 17. https://yandex.ru/patents/doc/RU2434613C1_20111127</mixed-citation></citation-alternatives></ref><ref id="cit96"><label>96</label><citation-alternatives><mixed-citation xml:lang="ru">Maki H., Mori S., Imai H. Autologous Scleral Pocket Technique for Ahmed Glaucoma Valve Implantation with Pars Plana Tube Insertion for Neovascular Glaucoma. J Clin Med 2021; 10:1606. https://doi.org/10.3390/jcm10081606.</mixed-citation><mixed-citation xml:lang="en">Maki H., Mori S., Imai H. Autologous Scleral Pocket Technique for Ahmed Glaucoma Valve Implantation with Pars Plana Tube Insertion for Neovascular Glaucoma. J Clin Med 2021; 10:1606. https://doi.org/10.3390/jcm10081606.</mixed-citation></citation-alternatives></ref><ref id="cit97"><label>97</label><citation-alternatives><mixed-citation xml:lang="ru">Iwasaki K., Arimura S., Takihara Y. Prospective cohort study of corneal endothelial cell loss after Baerveldt glaucoma implantation. PLoS ONE 2018; 13:e0201342. https://doi.org/10.1371/journal.pone.0201342.</mixed-citation><mixed-citation xml:lang="en">Iwasaki K., Arimura S., Takihara Y. Prospective cohort study of corneal endothelial cell loss after Baerveldt glaucoma implantation. PLoS ONE 2018; 13:e0201342. https://doi.org/10.1371/journal.pone.0201342.</mixed-citation></citation-alternatives></ref><ref id="cit98"><label>98</label><citation-alternatives><mixed-citation xml:lang="ru">Mori S., Sotani N., Ueda K., Sakamoto M., et al. Three-year outcome of sulcus fixation of Baerveldt glaucoma implant surgery. Acta Ophthalmol 2021; 99(8):1435-1441. https://doi.org/10.1111/aos.14839.</mixed-citation><mixed-citation xml:lang="en">Mori S., Sotani N., Ueda K., Sakamoto M., et al. Three-year outcome of sulcus fixation of Baerveldt glaucoma implant surgery. Acta Ophthalmol 2021; 99(8):1435-1441. https://doi.org/10.1111/aos.14839.</mixed-citation></citation-alternatives></ref><ref id="cit99"><label>99</label><citation-alternatives><mixed-citation xml:lang="ru">Elbaklish K. H., Gomaa W. A. A One-Year Follow-Up of Two Ahmed Glaucoma Valve Models (S2 and FP7) for Refractory Glaucoma: A Prospective Randomized Trial. Clin Ophthalmol 2020; 14:693–705. https://doi.org/10.2147/OPTH.S224653.</mixed-citation><mixed-citation xml:lang="en">Elbaklish K. H., Gomaa W. A. A One-Year Follow-Up of Two Ahmed Glaucoma Valve Models (S2 and FP7) for Refractory Glaucoma: A Prospective Randomized Trial. Clin Ophthalmol 2020; 14:693–705. https://doi.org/10.2147/OPTH.S224653.</mixed-citation></citation-alternatives></ref><ref id="cit100"><label>100</label><citation-alternatives><mixed-citation xml:lang="ru">Eibschitz-Tsimhoni M., Schertzer R.M., Musch D.C., Moroi SE. Incidence and management of encapsulated cysts following Ahmed glaucoma valve insertion. J Glaucoma 2005; 14(4):276–279. https://doi.org/10.1097/01.ijg.0000169391.94555.c1.</mixed-citation><mixed-citation xml:lang="en">Eibschitz-Tsimhoni M., Schertzer R.M., Musch D.C., Moroi SE. Incidence and management of encapsulated cysts following Ahmed glaucoma valve insertion. J Glaucoma 2005; 14(4):276–279. https://doi.org/10.1097/01.ijg.0000169391.94555.c1.</mixed-citation></citation-alternatives></ref><ref id="cit101"><label>101</label><citation-alternatives><mixed-citation xml:lang="ru">Ozalp O., Ilguy S., Atalay E., Simsek T., et al. Risk factors for hypertensive phase after Ahmed glaucoma valve implantation. Int Ophthalmol 2022; 42(1):147–156. https://doi.org/10.1007/s10792-021-02009-3.</mixed-citation><mixed-citation xml:lang="en">Ozalp O., Ilguy S., Atalay E., Simsek T., et al. Risk factors for hypertensive phase after Ahmed glaucoma valve implantation. Int Ophthalmol 2022; 42(1):147–156. https://doi.org/10.1007/s10792-021-02009-3.</mixed-citation></citation-alternatives></ref><ref id="cit102"><label>102</label><citation-alternatives><mixed-citation xml:lang="ru">Pitukcheewanont O., Tantisevi V., Chansangpetch S., Rojanapongpun P. Factors related to hypertensive phase after glaucoma drainage device implantation. Clin Ophthalmol 2018; 12:1479–1486. https://doi.org/10.2147/OPTH.S166244.</mixed-citation><mixed-citation xml:lang="en">Pitukcheewanont O., Tantisevi V., Chansangpetch S., Rojanapongpun P. Factors related to hypertensive phase after glaucoma drainage device implantation. Clin Ophthalmol 2018; 12:1479–1486. https://doi.org/10.2147/OPTH.S166244.</mixed-citation></citation-alternatives></ref><ref id="cit103"><label>103</label><citation-alternatives><mixed-citation xml:lang="ru">Quaranta L., Floriani I., Hollander L., Poli D., et al. Needle revision with 5-fluorouracil for the treatment of Ahmed glaucoma valve filtering blebs: 5-fluorouracil needling revision can be a useful and safe tool in the management of failing Ahmed glaucoma valve filtering blebs. J Glaucoma 2016; 25(4):e367–371. https://doi.org/10.1097/IJG.0000000000000366.</mixed-citation><mixed-citation xml:lang="en">Quaranta L., Floriani I., Hollander L., Poli D., et al. Needle revision with 5-fluorouracil for the treatment of Ahmed glaucoma valve filtering blebs: 5-fluorouracil needling revision can be a useful and safe tool in the management of failing Ahmed glaucoma valve filtering blebs. J Glaucoma 2016; 25(4):e367–371. https://doi.org/10.1097/IJG.0000000000000366.</mixed-citation></citation-alternatives></ref><ref id="cit104"><label>104</label><citation-alternatives><mixed-citation xml:lang="ru">Shah A.A., WuDunn D., Cantor L.B. Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma. Am J Ophthalmol 2000; 129:455-460. https://doi.org/10.1016/s0002-9394(99)00410-9.</mixed-citation><mixed-citation xml:lang="en">Shah A.A., WuDunn D., Cantor L.B. Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucoma. Am J Ophthalmol 2000; 129:455-460. https://doi.org/10.1016/s0002-9394(99)00410-9.</mixed-citation></citation-alternatives></ref><ref id="cit105"><label>105</label><citation-alternatives><mixed-citation xml:lang="ru">Lee S. E., Kim K. N., Kim W. J., et al. Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation. Korean J Ophthalmol 2019; 33(3):214-221. https://doi.org/10.3341/kjo.2018.0110.</mixed-citation><mixed-citation xml:lang="en">Lee S. E., Kim K. N., Kim W. J., et al. Encapsulated Bleb Excision with Collagen Matrix Implantation Following Failed Ahmed Glaucoma Valve Implantation. Korean J Ophthalmol 2019; 33(3):214-221. https://doi.org/10.3341/kjo.2018.0110.</mixed-citation></citation-alternatives></ref><ref id="cit106"><label>106</label><citation-alternatives><mixed-citation xml:lang="ru">Жаворонков С.А., Гурьева Н.В., Югай А.Г., Махмутов В.Ю., и др. Применение ПТФЭ мембран для профилактики фиброзирования при имплантации Ahmed дренажа при рефрактерной глаукоме. Офтальмология 2016; 13(3):151–156. https://doi.org/10.18008/1816–5095–2016-3–151–156.</mixed-citation><mixed-citation xml:lang="en">Zhavoronkov S.A., Gureva N.V., Yugai A.G., Makhmutov V.Y., Yugai S.A. The use of PTFE membranes with Ahmed Glaucoma Valve for treatment refractive glaucoma. Ophthalmology in Russ 2016; 13(3):151– 156. https://doi.org/10.18008/1816–5095–2016-3–151–156.</mixed-citation></citation-alternatives></ref><ref id="cit107"><label>107</label><citation-alternatives><mixed-citation xml:lang="ru">Расческов А. Ю. Способ профилактики рубцевания фильтрационной подушки при проведении антиглаукоматозных операцией с имплантацией дренажа клапанного типа Ahmed. Заявка на патент 2022122598/14 от 27.06.2022.</mixed-citation><mixed-citation xml:lang="en">Rascheskov A. Yu. Method of encapsulated bleb scarring preventing in Ahmed glaucoma valve implantion. Patent application 2022122598/14 dated 06/27/2022.</mixed-citation></citation-alternatives></ref><ref id="cit108"><label>108</label><citation-alternatives><mixed-citation xml:lang="ru">Pham C., Radclife N. M., Vu D. M. Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma. Clin Ophthalmol 2018; 12:2607–2615. https://doi.org/10.2147/OPTH.S186369.</mixed-citation><mixed-citation xml:lang="en">Pham C., Radclife N. M., Vu D. M. Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma. Clin Ophthalmol 2018; 12:2607–2615. https://doi.org/10.2147/OPTH.S186369.</mixed-citation></citation-alternatives></ref><ref id="cit109"><label>109</label><citation-alternatives><mixed-citation xml:lang="ru">Alvarado J.A., Hollander D.A., Juster R.P., Lee L.C. Ahmed valve implantation with adjunctive mitomycin C and 5-fluorouracil: longterm outcomes. Am J Ophthalmol 2008; 146(2):276–284. https://doi.org/10.1016/j.ajo.2008.04.008.</mixed-citation><mixed-citation xml:lang="en">Alvarado J.A., Hollander D.A., Juster R.P., Lee L.C. Ahmed valve implantation with adjunctive mitomycin C and 5-fluorouracil: longterm outcomes. Am J Ophthalmol 2008; 146(2):276–284. https://doi.org/10.1016/j.ajo.2008.04.008.</mixed-citation></citation-alternatives></ref><ref id="cit110"><label>110</label><citation-alternatives><mixed-citation xml:lang="ru">Mahdy R.A.R. Adjunctive use of bevacizumab versus mitomycin C with Ahmed valve implantation in treatment of pediatric glaucoma. J Glaucoma 2011; 20(7):458–463. https://doi.org/10.1097/IJG.0b013e3181efbea5.</mixed-citation><mixed-citation xml:lang="en">Mahdy R.A.R. Adjunctive use of bevacizumab versus mitomycin C with Ahmed valve implantation in treatment of pediatric glaucoma. J Glaucoma 2011; 20(7):458–463. https://doi.org/10.1097/IJG.0b013e3181efbea5.</mixed-citation></citation-alternatives></ref><ref id="cit111"><label>111</label><citation-alternatives><mixed-citation xml:lang="ru">Yazdani S., Mahboobipour H., Pakravan M., Doozandeh A., et al. Adjunctive Mitomycin C or amniotic membrane transplantation for Ahmed glaucoma valve implantation: a randomized clinical trial. J Glaucoma 2016; 25(5):415–421. https://doi.org/10.1097/IJG.0000000000000256.</mixed-citation><mixed-citation xml:lang="en">Yazdani S., Mahboobipour H., Pakravan M., Doozandeh A., et al. Adjunctive Mitomycin C or amniotic membrane transplantation for Ahmed glaucoma valve implantation: a randomized clinical trial. J Glaucoma 2016; 25(5):415–421. https://doi.org/10.1097/IJG.0000000000000256.</mixed-citation></citation-alternatives></ref><ref id="cit112"><label>112</label><citation-alternatives><mixed-citation xml:lang="ru">Costa V.P., Azuara-Blanco A., Netland P.A., Lesk M.R., et al. Efficacy and safety of adjunctive mitomycin C during Ahmed glaucoma valve implantation: a prospective randomized clinical trial. Ophthalmology 2004; 111(6):1071–1076. https://doi.org/10.1016/j.ophtha.2003.09.037.</mixed-citation><mixed-citation xml:lang="en">Costa V.P., Azuara-Blanco A., Netland P.A., Lesk M.R., et al. Efficacy and safety of adjunctive mitomycin C during Ahmed glaucoma valve implantation: a prospective randomized clinical trial. Ophthalmology 2004; 111(6):1071–1076. https://doi.org/10.1016/j.ophtha.2003.09.037.</mixed-citation></citation-alternatives></ref><ref id="cit113"><label>113</label><citation-alternatives><mixed-citation xml:lang="ru">Al-Mobarak F., Khan A.O. Two-year survival of Ahmed valve implantation in the first 2 years of life with and without intraoperative mitomycin-C. Ophthalmology 2009; 116(10):1862–1865. https://doi.org/10.1016/j.ophtha.2009.03.030.</mixed-citation><mixed-citation xml:lang="en">Al-Mobarak F., Khan A.O. Two-year survival of Ahmed valve implantation in the first 2 years of life with and without intraoperative mitomycin-C. Ophthalmology 2009; 116(10):1862–1865. https://doi.org/10.1016/j.ophtha.2009.03.030.</mixed-citation></citation-alternatives></ref><ref id="cit114"><label>114</label><citation-alternatives><mixed-citation xml:lang="ru">Chaku M., Netland P.A., Ishida K., Rhee D.J. Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery. Clin Ophthalmol 2016; 10:547-553. https://doi.org/10.2147/OPTH.S104029.</mixed-citation><mixed-citation xml:lang="en">Chaku M., Netland P.A., Ishida K., Rhee D.J. Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery. Clin Ophthalmol 2016; 10:547-553. https://doi.org/10.2147/OPTH.S104029.</mixed-citation></citation-alternatives></ref><ref id="cit115"><label>115</label><citation-alternatives><mixed-citation xml:lang="ru">Scott G.R., Weizer J.S., Moroi S.E., et al. Can topical ketorolac 0.5% improve the function of Ahmed_glaucoma drainage devices? Ophthalmic Surg Lasers Imaging 2011; 42:190-195. https://doi.org/10.3928/15428877-20110324-03.</mixed-citation><mixed-citation xml:lang="en">Scott G.R., Weizer J.S., Moroi S.E., et al. Can topical ketorolac 0.5% improve the function of Ahmed_glaucoma drainage devices? Ophthalmic Surg Lasers Imaging 2011; 42:190-195. https://doi.org/10.3928/15428877-20110324-03.</mixed-citation></citation-alternatives></ref><ref id="cit116"><label>116</label><citation-alternatives><mixed-citation xml:lang="ru">Almatlouh A., Bach-Holm D., Kessel L. Steroids and nonsteroidal anti-inflammatory drugs in the postoperative regime after trabeculectomydwhich provides the better outcome? Asystematic review and meta-analysis. Acta Ophthalmol 2019; 97:146-157. https://doi.org/10.1111/aos.13919.</mixed-citation><mixed-citation xml:lang="en">Almatlouh A., Bach-Holm D., Kessel L. Steroids and nonsteroidal anti-inflammatory drugs in the postoperative regime after trabeculectomydwhich provides the better outcome? Asystematic review and meta-analysis. Acta Ophthalmol 2019; 97:146-157. https://doi.org/10.1111/aos.13919.</mixed-citation></citation-alternatives></ref><ref id="cit117"><label>117</label><citation-alternatives><mixed-citation xml:lang="ru">Kao B.W., Fong C.W., Yu Y., Ying G.S., et al. Surgical Outcomes of Ahmed Glaucoma Valve Implantation with Postoperative Use of Prednisolone Acetate versus Difluprednate. Ophthalmol Glaucoma 2022; 5(5):468-475. https://doi.org/10.1016/j.ogla.2022.03.003.</mixed-citation><mixed-citation xml:lang="en">Kao B.W., Fong C.W., Yu Y., Ying G.S., et al. Surgical Outcomes of Ahmed Glaucoma Valve Implantation with Postoperative Use of Prednisolone Acetate versus Difluprednate. Ophthalmol Glaucoma 2022; 5(5):468-475. https://doi.org/10.1016/j.ogla.2022.03.003.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
