<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glaucoma</journal-id><journal-title-group><journal-title xml:lang="ru">Национальный журнал Глаукома</journal-title><trans-title-group xml:lang="en"><trans-title>National Journal glaucoma</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2078-4104</issn><issn pub-type="epub">2311-6862</issn><publisher><publisher-name>Federal State Budgetary Institution of Science “Krasnov Research Institute of Eye Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.53432/2078-4104-2026-25-2-31-37</article-id><article-id custom-type="elpub" pub-id-type="custom">glaucoma-625</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ СТАТЬИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL ARTICLES</subject></subj-group></article-categories><title-group><article-title>Сравнение транспальпебральной тонометрии с роговично компенсированным внутриглазным давлением</article-title><trans-title-group xml:lang="en"><trans-title>Comparison of transpalpebral tonometry with corneal-compensated intraocular pressure</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0005-3960-1676</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Штиуи</surname><given-names>М.</given-names></name><name name-style="western" xml:lang="en"><surname>Chtioui</surname><given-names>М.</given-names></name></name-alternatives><bio xml:lang="ru"><p>аспирант </p><p>119991, Москва, ул. Трубецкая, 8, стр. 2 </p></bio><bio xml:lang="en"><p>postgraduate student </p><p>8-2 Trubetskaya St., Moscow, 119991 </p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6397-449X</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Косова</surname><given-names>Д. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Kosova</surname><given-names>J. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>младший научный сотрудник </p><p>119021, Москва, ул. Россолимо, 11, корп. А, Б </p></bio><bio xml:lang="en"><p>junior researcher </p><p>11A Rossolimo St., Moscow, 119021 </p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8438-1872</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Сипливый</surname><given-names>В. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Siplivy</surname><given-names>V. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Сипливый Владимир Иванович, к.м.н., доцент, эксперт </p><p>119991, Москва, ул. Трубецкая, 8, стр. 2 </p><p>115478, Москва, Каширское шоссе, 24, стр. 16 </p></bio><bio xml:lang="en"><p>Cand. Sci. (Med.), Associate Professor, Expert </p><p>8-2 Trubetskaya St., Moscow, 119991 </p><p>24-16 Kashirskoe highway, Moscow, 115478 </p></bio><email xlink:type="simple">siplivy_v@mail.ru</email><xref ref-type="aff" rid="aff-3"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-0141-0568</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Войтович</surname><given-names>В. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Voytovich</surname><given-names>V. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>врач-офтальмолог </p><p>19991, Москва, ул. Трубецкая, 8, стр. 2 </p></bio><bio xml:lang="en"><p>ophthalmologist </p><p>8-2 Trubetskaya St., Moscow, 119991 </p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГАОУ ВО Первый МГМУ им. И.М. Сеченова Минздрава России (Сеченовский Университет)</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Sechenov First Moscow State Medical University</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГБНУ «НИИГБ им. М.М. Краснова»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Krasnov Research Institute of Eye Diseases</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>ФГАОУ ВО Первый МГМУ им. И.М. Сеченова Минздрава России (Сеченовский Университет) ; ФГБУ «ВНИИИМТ» Росздравнадзора</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Sechenov First Moscow State Medical University ; Russian Scientific and Research Institute for Medical Engineering</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>19</day><month>05</month><year>2026</year></pub-date><volume>25</volume><issue>2</issue><fpage>31</fpage><lpage>37</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Штиуи М., Косова Д.В., Сипливый В.И., Войтович В.В., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Штиуи М., Косова Д.В., Сипливый В.И., Войтович В.В.</copyright-holder><copyright-holder xml:lang="en">Chtioui М., Kosova J.V., Siplivy V.I., Voytovich V.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.glaucomajournal.ru/jour/article/view/625">https://www.glaucomajournal.ru/jour/article/view/625</self-uri><abstract><sec><title>ЦЕЛЬ</title><p>ЦЕЛЬ. Оценить точность и повторяемость измерений внутриглазного давления (ВГД) транспальпебральным тонометром в сравнении со значением роговично компенсированного ВГД.</p></sec><sec><title>МЕТОДЫ</title><p>МЕТОДЫ. Исследование проводили в группе здоровых испытуемых и пациентов с глаукомой, по 50 человек в каждой. Транспальпебральные измерения проводили тонометром «Тонотест» (АО «Елатомский приборный завод», Россия), роговично компенсированное ВГД измеряли с помощью анализатора биомеханических свойств глаза Ocular Resonse Analyzer (Reichert Inc., США). На каждом глазу проводили по 5 последовательных транспальпебральных замеров и повторный замер после приведения прибора в начальное положение.</p></sec><sec><title>РЕЗУЛЬТАТЫ</title><p>РЕЗУЛЬТАТЫ. Возраст испытуемых первой группы составил (M±σ) 21,54±2,82 год; 21 мужчина и 29 женщин. В группе пациентов с глаукомой — 66,34±13,53 лет; 17 мужчин и 33 женщины.</p><p>При сравнении транспальпебральных замеров с роговично компенсированным ВГД методом Бланда – Альтмана средняя ошибка измерений (Bias) составила -0,36 мм рт.ст. Верхний (ULOA) и нижний (LLOA) пределы 95% согласия составили соответственно +7,77 и -8,49 мм рт.ст. Выявлено также достоверное (р&lt;0,001) различие между ошибками измерения в группе здоровых добровольцев и пациентов с глаукомой. Сравнение первого и повторного транспальпебральных замеров показало их хорошую согласованность. Средняя ошибка измерений (Bias) составила -0,64 мм рт.ст. Верхний (ULOA) и нижний (LLOA) пределы 95% согласия составили соответственно +0,77 и -2,06 мм рт.ст.</p><p>Регрессионный анализ последовательных транспальпебральных замеров показал тенденцию к снижению результатов: каждое последующее измерение оказалось в среднем на 0,19 мм рт.ст. ниже предыдущего (доверительный интервал 0,02–0,38 мм рт.ст.).</p></sec><sec><title>ЗАКЛЮЧЕНИЕ</title><p>ЗАКЛЮЧЕНИЕ. Транспальпебральная тонометрия не подходит для замены «роговичных» методов измерения ВГД при диагностике глаукомы из-за существенной погрешности. Однако, несмотря на отмеченные ограничения, она имеет высокую ценность для скрининга и динамического наблюдения благодаря таким преимуществам, как высокая повторяемость замеров, неинвазивность и техническая простота.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>PURPOSE</title><p>PURPOSE. To evaluate the accuracy and repeatability of intraocular pressure (IOP) measurements using a transpalpebral tonometer compared to corneal-compensated intraocular pressure.</p></sec><sec><title>METHODS</title><p>METHODS. The study included 50 healthy subjects and the same number of glaucoma patients. Transpalpebral measurements were performed using the Tonotest tonometer (AO Yelatomskiy priborniy zavod, Russia), cornealcompensated IOP was measured using the Ocular Response Analyzer (Reichert Inc., USA). Five consecutive transpalpebral measurements were obtained for each eye, followed by a repeat measurement after returning the device to its initial position.</p></sec><sec><title>RESULTS</title><p>RESULTS. The age of subjects in first group was (M±σ) 21.54±2.82 years; 21 men and 29 women. The age of the patients in the glaucoma group was 66.34±13.53 years; 17 men and 33 women.</p><p>When comparing transpalpebral measurements with corneal-compensated IOP using the Bland–Altman method, the mean measurement error (bias) was -0.36 mm Hg. The upper (ULOA) and lower (LLOA) limits of 95% agreement were +7.77 and –8.49 mm Hg, respectively. A significant (p&lt;0.001) difference was also found between the measurement error in the group of healthy volunteers and patients with glaucoma. Comparison of the initial and repeated transpalpebral measurements demonstrated their good agreement. The mean bias was –0.64 mm Hg. ULOA and LLOA were +0.77 and –2.06 mm Hg, respectively.</p><p>Regression analysis of sequential transpalpebral measurements revealed a trend toward decreased results, with each subsequent measurement being, on average, 0.19 mm Hg lower than the previous one (confidence interval 0.02–0.38 mm Hg).</p></sec><sec><title>CONCLUSION</title><p>CONCLUSION. Transpalpebral tonometry is not a suitable replacement for corneal IOP measurement methods in the initial diagnosis of glaucoma due to substantial measurement error. However, despite these limitations, it is highly valuable for screening and follow-up due to its advantages, such as high repeatability, noninvasiveness, and technical simplicity.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>внутриглазное давление</kwd><kwd>транспальпебральная тонометрия</kwd><kwd>Тонотест</kwd><kwd>ORA</kwd></kwd-group><kwd-group xml:lang="en"><kwd>intraocular pressure</kwd><kwd>transpalpebral tonometry</kwd><kwd>Tonotest</kwd><kwd>ORA</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Брежнев А.Ю., Егоров Е.А., Еричев В.П. и др. «Ландшафт» глаукомы в России, странах СНГ и Восточной Европы: что поменялось за 15 лет? РМЖ Клиническая офтальмология 2023; 23(2):73-79. https://doi.org/10.32364/2311-7729-2023-23-2-73-79.</mixed-citation><mixed-citation xml:lang="en">Brezhnev A.Yu., Egorov E.A., Erichev V.P. et al. Glaucoma "landscape" in Russia, CIS and Eastern European countries: what has changed over 15 years? RMJ Clinical Ophthalmology 2023; 23(2):73-79. https://doi.org/10.32364/2311-7729-2023-23-2-73-79.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Vaajanen A., Purola P., Ojamo M. et al. Changes in incidence and severity of visual impairment due to glaucoma during 40 years - a registerbased study in Finland. Acta Ophthalmol 2022; 100(5):534-540. https://doi.org/10.1111/aos.15030.</mixed-citation><mixed-citation xml:lang="en">Vaajanen A., Purola P., Ojamo M. et al. Changes in incidence and severity of visual impairment due to glaucoma during 40 years - a registerbased study in Finland. Acta Ophthalmol 2022; 100(5):534-540. https://doi.org/10.1111/aos.15030.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Аветисов С.Э., Еричев В.П., Антонов А.А., Полева Р.П., Козлова И.В., Макарова А.С. Современные достижения в диагностике и лечении глаукомы. Вестник офтальмологии 2023; 139(3.2):96-106. https://doi.org/10.17116/oftalma202313903296</mixed-citation><mixed-citation xml:lang="en">Avetisov SE, Erichev VP, Antonov AA, Poleva RP, Kozlova IV, Makarova AS. Modern achievements in the diagnosis and treatment of glaucoma. Vestnik oftal’mologii 2023; 139(3.2):96-106. https://doi.org/10.17116/oftalma202313903296</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Илларионова А.Р., Пилецкий Н.Г. Исследование достоверности показаний тонометра для измерения внутриглазного давления через веко (ТГДц-01 ПРА). РМЖ Клиническая офтальмология 2001; 2(2):55-56.</mixed-citation><mixed-citation xml:lang="en">Illarionova A. R., Piletsky N. G. A study of the reliability of the testimony of the tonometer for measuring intraocular pressure through the eyelid (Diaton-01 PRA). RMJ Clinical Ophthalmology 2001; 2(2): 55-56.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Нестеров А.П. Илларионова А.Р., Обруч Б.В. Новый транспальпебральный тонометр ТГДЦ-01 Diaton. Вестник офтальмологии 2007; 123(1):42-44.</mixed-citation><mixed-citation xml:lang="en">Nesterov A.P., Illarionova A.R., Obruch B.V. New transpalpebral tonometer TGDC-01 Diaton. Vestnik oftal’mologii 2007;123(1):42-44.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Аветисов С.Э., Еричев В.П., Антонов А.А. Диагностические возможности транспальпебральной тонометрии индикатором ИГД-03. Национальный журнал глаукома 2016; 15(3):17-23.</mixed-citation><mixed-citation xml:lang="en">Avetisov, S.E, Erichev V.P., Antonov A.A. Diagnostic capabilities of transpalpebral tonometry with the IGD-03 indicator. National journal glaucoma 2016; 15(3):17-23.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Alzuhairy S. Transpalpebral intraocular pressure measurement by Diaton compared to Goldman applanation tonometer in myopic eyes before and after transepithelial photorefractive keratectomy in Saudi Arabia. Int J Ophthalmol 2023; 16(3):375-381. https://doi.org/10.18240/ijo.2023.03.07.</mixed-citation><mixed-citation xml:lang="en">Alzuhairy S. Transpalpebral intraocular pressure measurement by Diaton compared to Goldman applanation tonometer in myopic eyes before and after transepithelial photorefractive keratectomy in Saudi Arabia. Int J Ophthalmol 2023; 16(3):375-381. https://doi.org/10.18240/ijo.2023.03.07.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Kobashi H. Evaluation of a new transpalpebral tonometer for selfmeasuring intraocular pressure. PLoS One 2024; 19(5):e0302568. https://doi.org/10.1371/journal.pone.0302568.</mixed-citation><mixed-citation xml:lang="en">Kobashi H. Evaluation of a new transpalpebral tonometer for selfmeasuring intraocular pressure. PLoS One 2024; 19(5):e0302568. https://doi.org/10.1371/journal.pone.0302568.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Montolío-Marzo E, Morales-Fernández L, Saenz-Frances San Baldomero F, García-Saenz S, García-Feijoo J, Piñero DP, Martínez-de-laCasa JM. Easyton® transpalpebral versus Perkins applanation tonometry in different populations. Int Ophthalmol 2023; 43(10):3491-3497. https://doi.org/10.1007/s10792-023-02754-7.</mixed-citation><mixed-citation xml:lang="en">Montolío-Marzo E, Morales-Fernández L, Saenz-Frances San Baldomero F, García-Saenz S, García-Feijoo J, Piñero DP, Martínez-de-laCasa JM. Easyton® transpalpebral versus Perkins applanation tonometry in different populations. Int Ophthalmol 2023; 43(10):3491-3497. https://doi.org/10.1007/s10792-023-02754-7.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Keller WJ, Haytac P, Nazarian T, Chawla K, Chang J. Transpalpebral measurement of intraocular pressure with the Tono-Pen XL, in a young, healthy, adult population. Medicine (Baltimore) 2025; 104(18):e42302. https://doi.org/10.1097/MD.0000000000042302.</mixed-citation><mixed-citation xml:lang="en">Keller WJ, Haytac P, Nazarian T, Chawla K, Chang J. Transpalpebral measurement of intraocular pressure with the Tono-Pen XL, in a young, healthy, adult population. Medicine (Baltimore) 2025; 104(18):e42302. https://doi.org/10.1097/MD.0000000000042302.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Штиуи М., Сипливый В.И., Косова Д.В., Асламазова А.Э. Приборы для самостоятельного измерения внутриглазного давления. Национальный журнал глаукома 2025; 24(2):73-83. https://doi.org/10.53432/2078-4104-2025-24-2-73-83</mixed-citation><mixed-citation xml:lang="en">Chtioui М., Siplivy V.I., Kosova J.V., Aslamazova A.E. Devices for intraocular pressure self-tonometry. National journal glukoma 2025; 24(2):73-83. https://doi.org/10.53432/2078-4104-2025-24-2-73-83</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
