<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">glaucoma</journal-id><journal-title-group><journal-title xml:lang="ru">Национальный журнал Глаукома</journal-title><trans-title-group xml:lang="en"><trans-title>National Journal glaucoma</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2078-4104</issn><issn pub-type="epub">2311-6862</issn><publisher><publisher-name>Federal State Budgetary Institution of Science “Krasnov Research Institute of Eye Diseases”</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">glaucoma-69</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ СТАТЬИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL ARTICLES</subject></subj-group></article-categories><title-group><article-title>Корреляции и поправочные коэффициенты при различных видах тонометрии. Сообщение 1</article-title><trans-title-group xml:lang="en"><trans-title>Correlation and correction factors for different types of tonometry. Report 1</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Волкова</surname><given-names>Н. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Volkova</surname><given-names>N. V.</given-names></name></name-alternatives><email xlink:type="simple">vnv-mntk@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Юрьева</surname><given-names>Т. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Yurieva</surname><given-names>T. N.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Швец</surname><given-names>Л. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Shvetz</surname><given-names>L. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Михалевич</surname><given-names>И. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Mikhalevich</surname><given-names>I. M.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Иркутский филиал ФГБУ «МНТК «Микрохирургия глаза» им. акад. С.Н. Федорова» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Irkutsk Branch of S. Fyodorov Eye Microsurgery Federal State Institution</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Иркутский государственный медицинский университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Irkutsk State Medical University</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>ГБОУ ДПО «Иркутская государственная медицинская академия последипломного образования» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Irkutsk Institute of Continuing Medical Education</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2015</year></pub-date><pub-date pub-type="epub"><day>17</day><month>01</month><year>2017</year></pub-date><volume>14</volume><issue>3</issue><fpage>11</fpage><lpage>18</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Волкова Н.В., Юрьева Т.Н., Швец Л.В., Михалевич И.М., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Волкова Н.В., Юрьева Т.Н., Швец Л.В., Михалевич И.М.</copyright-holder><copyright-holder xml:lang="en">Volkova N.V., Yurieva T.N., Shvetz L.V., Mikhalevich I.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.glaucomajournal.ru/jour/article/view/69">https://www.glaucomajournal.ru/jour/article/view/69</self-uri><abstract><p>ЦЕЛЬ. Сравнительный анализ результатов тонометрии по Маклакову (МТ), аппланационной тонометрии по Гольдману (Goldman applanation tonometry, GT) и микроконтактной тонометрии с помощью тонометра Icare (Icare rebound tonometry, RT) в группах: «все пациенты», «низкая», «средняя» и «высокая» нормы внутриглазного давления (ВГД) с целью их правильной интерпретации, определения единых поправочных коэффициентов и точек приложения в клинической практике. МЕТОДЫ. В каждом из 294 случаев (147 человек) выполнено измерение офтальмотонуса указанными способами в последовательности - RT, GT, МТ. Для сравнительного анализа результатов измерений и определения поправочных коэффициентов применены методы Bland-Altman и простой регрессионный анализ. РЕЗУЛЬТАТЫ. Разница значений уровней ВГД в группе «все пациенты» составила: GT - MT 4,6±1,9; GT - RT 1,9±2,9; MT - RT 6,7±2,7 мм рт.ст. В группах «средней» и «низкой» норм разница значений ВГД сопоставима с группой «все пациенты». Наиболее существенной оказалась разница в диапазоне «высокой» нормы ВГД: GT - MT 5,6±2,1; GT - RT 2,49±3,5; MT - RT 8±3,6 мм рт.ст. Высокое значение коэффициента детерминации (r2) при сравнении методов MT - GT подтверждает точность полученных значений офтальмотонуса. Низкое значение r2 при сравнении методов MT - RT и GT - RT свидетельствуют об ориентировочном определении уровня ВГД методом Icare. ЗАКЛЮЧЕНИЕ. Методы тонометрии по Goldmann (Р0) и по Маклакову (Pt) являются «эталонными». Альтернативная методика Icare указывает на уровень ВГД, приближенный к уровню истинного ВГД, но имеет большой разброс отклонений, что не позволяет отнести её к разряду прецизионных. Существенный разброс разницы измерений в диапазоне «высокой» нормы ВГД подчеркивает необходимость оценки его с позиции «стартового понятия», с использованием исключительно прецизионных методик. Тонометрия Icare применима для скрининговых профилактических осмотров (в т. ч. в педиатрической практике), суточного мониторинга и самоконтроля уровня ВГД, а также в широкой практике раннего послеоперационного периода, с учетом использования выявленных поправочных коэффициентов.</p></abstract><trans-abstract xml:lang="en"><p>PURPOSE: Comparative analysis of the results of Mak-lakov tonometry (MT), Goldman applanation tonometry (GT) and Icare rebound tonometry (rt) in the following groups: «all patients», «low», «medium» and «high» IOP rate for the purpose of its proper interpretation, determination of unified correction coefficients and the points of application in the clinical practice. METHODS: In each of 294 cases (147 persons) IOP was measured by the above methods in the following order - RT, GT, MT. For a comparative analysis of measurement results and determination of correction factors Bland-Altman methods and simple regression analysis were applied. RESULTS: The difference in IOP level values in the «all patients» group: GT - MT was 4.6±1.9; GT - RT 1.9±2.9; MT - RT 6.7±2.7 mm Hg. In the groups of «average» and «low» standards IOP difference is comparable with the «all patients» group. The most significant difference was found in the range of «high» rate of IOP: GT - MT 5.6±2.1; GT - RT 2.49±3.5; MT - RT 8.0±3.6 mm Hg. The high value of the coefficient of determination (r2) MT and GT confirms the accuracy of data. The low value of r2 when comparing the MT - RT and GT - RT indicates the approximate determination of IOP level by means of the Icare tonometer. CONCLUSION: Goldmann (P0) and Maklakov tonometry (Pt) are considered to be the tonometry benchmark. Alternative method of Icare rebound tonometry indicates the level of IOP, close to the level of true IOP, but has a large spread of deviations that cannot be attributed to the category of its precision. The significant dispersion in the measurement differences in range of «high» rate of IOP emphasizes the need to assess it in terms of «starting concepts», using only high-precision techniques. Icare tonometry is applicable for screening examinations (including pediatric), daily monitoring and self-control of IOP level, as well as in the general practice of «early» postoperative period, taking into account the use of identified correction factors.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>глаукома</kwd><kwd>тонометрия</kwd><kwd>тонометрия по Маклакову</kwd><kwd>тонометрия по Goldman</kwd><kwd>тонометр Icare</kwd><kwd>истинное и тонометрическое внутриглазное давление</kwd><kwd>методы тонометрии</kwd><kwd>glaucoma</kwd><kwd>tonometry</kwd><kwd>Maklakov tonometry</kwd><kwd>Goldman tonometry</kwd><kwd>Icare tonometer</kwd><kwd>actual and tonometric intraocular pressure</kwd><kwd>tonometry methods</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Любимов Г.А. История развития и биомеханическое содержание измерения внутриглазного давления по методу Маклакова. Глаукома 2006; 1: 43-49</mixed-citation><mixed-citation xml:lang="en">Любимов Г.А. История развития и биомеханическое содержание измерения внутриглазного давления по методу Маклакова. Глаукома 2006; 1: 43-49</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Нестеров А.П., Бунин А.Я., Кацнельсон Л.А. Внутриглазное давление. Физиология и патология. М.: Наука, 1974; 381 с</mixed-citation><mixed-citation xml:lang="en">Нестеров А.П., Бунин А.Я., Кацнельсон Л.А. Внутриглазное давление. Физиология и патология. М.: Наука, 1974; 381 с</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Gordon M.O., Beiser J.A., Brandt J.D. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 2002; 120(6): 714-720</mixed-citation><mixed-citation xml:lang="en">Gordon M.O., Beiser J.A., Brandt J.D. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 2002; 120(6): 714-720</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Copt R.P., Thomas R., Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol 1999; 117: 14-16.</mixed-citation><mixed-citation xml:lang="en">Copt R.P., Thomas R., Mermoud A. Corneal thickness in ocular hypertension, primary open-angle glaucoma, and normal tension glaucoma. Arch Ophthalmol 1999; 117: 14-16.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Manni G., Oddone F., Parisi V. et al. Intraocular pressure and central corneal thickness. Prog Brain Res 2008; 173: 25-30.</mixed-citation><mixed-citation xml:lang="en">Manni G., Oddone F., Parisi V. et al. Intraocular pressure and central corneal thickness. Prog Brain Res 2008; 173: 25-30.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Shimmyo M., Ross A.J., Moy A. et al. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics and African-Americans. Am J Ophthalmol 2003; 136: 603-613.</mixed-citation><mixed-citation xml:lang="en">Shimmyo M., Ross A.J., Moy A. et al. Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics and African-Americans. Am J Ophthalmol 2003; 136: 603-613.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Doughty M.J., Zaman M.L. Human corneal thickness and its impact on intraocular pressure measures: a review end metaanalysis approach. Surv Ophthalmol 2000; 44: 367-408.</mixed-citation><mixed-citation xml:lang="en">Doughty M.J., Zaman M.L. Human corneal thickness and its impact on intraocular pressure measures: a review end metaanalysis approach. Surv Ophthalmol 2000; 44: 367-408.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Mansouri K., Leite M.T., Weinreb R.N. et al. Association between corneal biomechanical properties and glaucoma severity. Am J Ophthalmol 2012; 153(3): 419-427.</mixed-citation><mixed-citation xml:lang="en">Mansouri K., Leite M.T., Weinreb R.N. et al. Association between corneal biomechanical properties and glaucoma severity. Am J Ophthalmol 2012; 153(3): 419-427.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Аветисов С.Э., Бубнова И.А., Петров С.Ю. и др. Особенности биомеханических свойств фиброзной оболочки глаза у пациентов с первичной открытоугольной глаукомой. Национальный журнал глаукома 2012; 4: 7-11.</mixed-citation><mixed-citation xml:lang="en">Аветисов С.Э., Бубнова И.А., Петров С.Ю. и др. Особенности биомеханических свойств фиброзной оболочки глаза у пациентов с первичной открытоугольной глаукомой. Национальный журнал глаукома 2012; 4: 7-11.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Лебедев О.И., Калижникова Е.А., Яровский А.Е. Топ-лист ведения пациентов с глаукомой: тонометрия. Национальный журнал глаукома 2013; 4: 43-51</mixed-citation><mixed-citation xml:lang="en">Лебедев О.И., Калижникова Е.А., Яровский А.Е. Топ-лист ведения пациентов с глаукомой: тонометрия. Национальный журнал глаукома 2013; 4: 43-51</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Еричев В.П., Антонов А.А. Сравнение результатов тонометрии с помощью прибора Icare и метода двунаправленной пневмоаппланации роговицы. Национальный журнал глаукома 2012; 4: 14-19</mixed-citation><mixed-citation xml:lang="en">Еричев В.П., Антонов А.А. Сравнение результатов тонометрии с помощью прибора Icare и метода двунаправленной пневмоаппланации роговицы. Национальный журнал глаукома 2012; 4: 14-19</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Goldmann H., Schmidt T. Applanation tonometry. Ophthalmologica 1957; 134: 221-242</mixed-citation><mixed-citation xml:lang="en">Goldmann H., Schmidt T. Applanation tonometry. Ophthalmologica 1957; 134: 221-242</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Маклаков А.Н. Офтальмотонометрия. Мед Образование 1884; 24: 1092-1095</mixed-citation><mixed-citation xml:lang="en">Маклаков А.Н. Офтальмотонометрия. Мед Образование 1884; 24: 1092-1095</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Ланг Т.А., Сесик М. Как описать статистику в медицине. Аннотированное руководство для авторов, редакторов и рецензентов / Под ред. В.П. Леонова. М.: Практическая медицина; 2011; 480 с</mixed-citation><mixed-citation xml:lang="en">Ланг Т.А., Сесик М. Как описать статистику в медицине. Аннотированное руководство для авторов, редакторов и рецензентов / Под ред. В.П. Леонова. М.: Практическая медицина; 2011; 480 с</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Altman D.G., Bland J.M. Measurement in medicine: the analysis of method comparison studies. The Statistician 1983; 32: 307-317. doi: 10.2307/2987937</mixed-citation><mixed-citation xml:lang="en">Altman D.G., Bland J.M. Measurement in medicine: the analysis of method comparison studies. The Statistician 1983; 32: 307-317. doi: 10.2307/2987937</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Godfrey K. Simple linear regression in medical research. In: Bailar J.C., Mosteller F., eds. Medical Uses of Statistics, 2nd ed. Boston: NEJM Book; 1992: 201-232.</mixed-citation><mixed-citation xml:lang="en">Godfrey K. Simple linear regression in medical research. In: Bailar J.C., Mosteller F., eds. Medical Uses of Statistics, 2nd ed. Boston: NEJM Book; 1992: 201-232.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Глаукома. Национальное руководство / Под ред. Е.А. Егорова. М.: ГОЭТАР-Медиа, 2013; 824 с.</mixed-citation><mixed-citation xml:lang="en">Глаукома. Национальное руководство / Под ред. Е.А. Егорова. М.: ГОЭТАР-Медиа, 2013; 824 с.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Terminology and guidelines for glaucoma. 4th Edition / Ed. EGS-European Glaucoma Society. London: Publicomm, 2014: 191 p.</mixed-citation><mixed-citation xml:lang="en">Terminology and guidelines for glaucoma. 4th Edition / Ed. EGS-European Glaucoma Society. London: Publicomm, 2014: 191 p.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Щуко А.Г., Юрьева Т.Н. Чекмарева Л.Т. и др. Дифференциальная диагностика редких форм глаукомы. Иркутск: Облмашинформ, 2004; 192 с.</mixed-citation><mixed-citation xml:lang="en">Щуко А.Г., Юрьева Т.Н. Чекмарева Л.Т. и др. Дифференциальная диагностика редких форм глаукомы. Иркутск: Облмашинформ, 2004; 192 с.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Нестеров А.П., Вургафт М.Б. Калибровочные таблицы для эластотонометра Филатова-Кальфа. Вестник офтальмологии 1972; 88(2): 20-25</mixed-citation><mixed-citation xml:lang="en">Нестеров А.П., Вургафт М.Б. Калибровочные таблицы для эластотонометра Филатова-Кальфа. Вестник офтальмологии 1972; 88(2): 20-25</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Baily C., Dooley I., Collins N. et al. The difference in intraocular pressure readings between 3 applanation tonometers is independent of central corneal thickness, in glaucomatous and nonglaucomatous eyes. J Glaucoma 2014; 23 (9): 14-19.</mixed-citation><mixed-citation xml:lang="en">Baily C., Dooley I., Collins N. et al. The difference in intraocular pressure readings between 3 applanation tonometers is independent of central corneal thickness, in glaucomatous and nonglaucomatous eyes. J Glaucoma 2014; 23 (9): 14-19.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Davies L.N., Bartlett Y., Vallen E. et al. Clinical evaluation of Rebound Tonometer. Acta Ophthalmol Scand 2004; 122: 1117-1121.</mixed-citation><mixed-citation xml:lang="en">Davies L.N., Bartlett Y., Vallen E. et al. Clinical evaluation of Rebound Tonometer. Acta Ophthalmol Scand 2004; 122: 1117-1121.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Thu S.Y., Sheu M.M., Thu A.H. et al. Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tonopen tonometry, and dynamic contour tonometry. Eye (Lond) 2009; 23: 1582-1588.</mixed-citation><mixed-citation xml:lang="en">Thu S.Y., Sheu M.M., Thu A.H. et al. Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tonopen tonometry, and dynamic contour tonometry. Eye (Lond) 2009; 23: 1582-1588.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Brusini P., Salvetat M.L., Zeppieri M. et al. Comparison of Icare tonometer with Goldmann apllanation tonometer in glaucoma patients. Glaucoma 2006; 15(3): 213-217.</mixed-citation><mixed-citation xml:lang="en">Brusini P., Salvetat M.L., Zeppieri M. et al. Comparison of Icare tonometer with Goldmann apllanation tonometer in glaucoma patients. Glaucoma 2006; 15(3): 213-217.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Национальное руководство по глаукоме: для практикующих врачей / Под ред. проф. Е.Ф. Егорова, проф. Ю.С. Астахова, проф. А.Г. Щуко. Изд. 2-е. М.: ГОЭТАР-Медиа, 2011; 280 с</mixed-citation><mixed-citation xml:lang="en">Национальное руководство по глаукоме: для практикующих врачей / Под ред. проф. Е.Ф. Егорова, проф. Ю.С. Астахова, проф. А.Г. Щуко. Изд. 2-е. М.: ГОЭТАР-Медиа, 2011; 280 с</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Казанова С.Ю. Ошибки измерения внутриглазного давления по Маклакову. Национальный журнал глаукома 2013; 4: 72-80</mixed-citation><mixed-citation xml:lang="en">Казанова С.Ю. Ошибки измерения внутриглазного давления по Маклакову. Национальный журнал глаукома 2013; 4: 72-80</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
